1. Sector : Health Services/Equipments
Installation of Shallow/medium/deep Tubewells as Per is 28001991 Supplying Erection, Testing of Fully Automatic Electric Control Panel Board for T/wells in Pump Chamber Consisting of Ms Sheet of Thickness 14 Gauge Duly Painted Box Type Floor Mounted Made of Angle Frame Containing 1 No. Fully Automatic Air Brake Starter Suitable for Motor of the Following Capacity, Min Switch of Suitable Range with Hrc Fuse, 1 No. Volt Meter (0 to 500 Volts), 1 No. Amp. Meter of 0 to 100 Amp. 3 Sets of Indicating Lamp Capacitor of Suitable Capacity and 1 No. Single Phase Preventers with the Timer Switch Including Wiring in Panel Board and Suitable Electric Energy Meter Wiring in Electric Control Panel Board Complete in All Respect as Per Specification Given in Schedule No. Ii, Including Mcb, Suitable, Capacitor, Wooden Box Etc as Per Site Requirement Complete in All Respect. 5. 30 Hp Motor Annual Mtc. Works for Water Supply, Supply and Jointing Three Core Submersible Flat Cables of Approved Make with Bare Bunched Copper Conductor Insulated and Sheathed with Pvc for Submersible Pump Motors /fountain Lights Etc with Voltage Grade 1100 Volts Marked with Is694, 1990 Including Cost of Jointing, Materials as Well as Carriage, Loading, Unloading Etc. Complete in All Respect Up to the Entire Satisfaction of Engineer- In-charge.
|
Value :
INR 41.93 K
*
|
INR 41.93 K
*
|
Due Date :
3 Days to go
|
01/04/2024
|
TID :70763211
Haryana
|
|
|
2. Sector : Health Services/Equipments
Bharog , Chhajju Majra , Group of 2 No. of Habitations Annual maintenance.works for Water Supply, Na Maintenance of Roads Removal of Existing Ipb By Manual Means and Disposal of Dismantled Material with All Lead and Lift as Per Technical Specification Clause 202.3, Na Maintenance of Roads Relaying of Available (removed and Stacked) Interlocking Paver Block Pavement Having Thickness 100mm/80 Mm/ 60 Mm (average = 80mm) as Per Drawings and Technical Specification Clause 1504, I Fixing Bell Mouths Bailing Out Water From the Trenches for Making New Connections in Fully Charged Pipe-lines
including Cleaning Trimming and Dressing the Trenches to Correct Alignment and Grade as Required By the Engineer-in-charge. Size of the Main with Which Connection is to Be Made. 1. Up to 200 Mm Internal Diametre, L Filter Media Providing and Fixing Cast Iron Detachable Joints Class-15 Marked with Is 8794 for Use with Asbestos
cement Pressure Pipes Complete with 2 Nos. Rubber Rings Marked with Is5382 and Is10292 and Appropriate Number of Nut and Bolts Marked with Is1363 Including Carriage, Loading, Unloading Etc. Complete in All Respects to the Satisfaction of the Engineer-in-charge. (excavation Will Be Paid Separately) 2. 100mm I/d Cid Joint, Civil Items (used Commonly in Electrical Works) 6. Digging of Pucca Road in Required Width for Laying of Cable /pipe Complete in All Respect Up to the Entire Satisfaction of Engineer-in Charge, Excavating Trenches of Required Width for Pipes, Cables, Etc Including Excavation for Sockets, and Dressing of Sides, Ramming of Bottoms, Depth Up to 1.5 M, Including Getting Out the Excavated Soil, and Then Returning the Soil as Required, in Layers Not Exceeding 20 Cm in Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. and Disposing of Surplus Excavated Soil as Directed, Within a Lead of 50 M 1.2. Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia, a Cement Concrete (cast in Situ) Providing and Laying in Position Cement Concrete of Specified Grade Excluding The
cost of Centering and Shuttering - All Work Below Plinth Level and Up to Floor Iv Level 6. 148 (1 Cement 4 Coarse Sand(zone-iii) 8 Graded Stone Aggregate 40 Mm Nominal Size), Na Rain Water Spouts and Pipes Providing and Fixing on Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming to is 13592 Type a, Including Jointing with Seal Ring Conforming to is 5382, Leaving 10 Mm Gap for Thermal Expansion, (i) Single Socketed Pipes. 2. 110 Mm Diameter, Na Rain Water Spouts and Pipes Providing and Fixing on Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories for Unplasticised Rigid Pvc Rain Water Pipes Conforming to is 13592 Type a, Including Jointing with Seal Ring Conforming to is 5382, Leaving 10 Mm Gap for Thermal Expansion. 5.2. Bend 87.5° 110 Mm Bend
|
Value :
INR 41.40 K
*
|
INR 41.40 K
*
|
Due Date :
3 Days to go
|
01/04/2024
|
TID :70803012
Haryana
|
|
|
3. Sector : Health Services/Equipments
Manglai , Khuddi , Group of 2 No. of Habitations Annual Mtc.works for Water Supply, Na Maintenance of Roads Removal of Existing Ipb By Manual Means and Disposal of Dismantled Material with All Lead and Lift as Per Technical Specification Clause 202.3, Na Maintenance of Roads Relaying of Available (removed and Stacked) Interlocking Paver Block Pavement Having Thickness 100mm/80 Mm/ 60 Mm (average = 80mm) as Per Drawings and Technical Specification Clause 1504, I Fixing Bell Mouths Bailing Out Water From the Trenches for Making New Connections in Fully Charged Pipe-lines
including Cleaning Trimming and Dressing the Trenches to Correct Alignment and Grade as Required By the Engineer-in-charge. Size of the Main with Which Connection is to Be Made. 1. Up to 200 Mm Internal Diametre, L Filter Media Providing and Fixing Cast Iron Detachable Joints Class-15 Marked with Is 8794 for Use with Asbestos Cement Pressure Pipes Complete with 2 Nos. Rubber Rings Marked with Is5382 and Is10292 and Appropriate Number of Nut and Bolts Marked with Is1363 Including Carriage, Loading, Unloading Etc. Complete in All Respects to the Satisfaction of the Engineer-in-charge. (excavation Will Be Paid Separately) 2. 100mm I/d Cid Joint, Civil Items (used Commonly in Electrical Works) 6. Digging of Pucca Road in Required Width for Laying of Cable /pipe Complete in All Respect Up to the Entire Satisfaction of Engineer-in Charge, Excavating Trenches of Required Width for Pipes, Cables, Etc Including Excavation for Sockets, and Dressing of Sides,
ramming of Bottoms, Depth Up to 1.5 M, Including Getting Out the Excavated Soil, and Then Returning the Soil as Required, in Layers Not Exceeding 20 Cm in Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. and Disposing of Surplus Excavated Soil as Directed, Within a Lead of 50 M 1.2. Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia, a Cement Concrete (cast in Situ) Providing and Laying in Position Cement Concrete of Specified Grade Excluding the Cost of Centering and Shuttering - All Work Below Plinth Level and Up to Floor Iv Level 6. 148 (1 Cement 4 Coarse Sand (zone-iii) 8 Graded Stone Aggregate 40 Mm Nominal Size), Na Rain Water Spouts and Pipes Providing and Fixing on Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming to is 13592 Type a, Including Jointing with Seal Ring Conforming to is 5382, Leaving 10 Mm Gap for Thermal Expansion, (i) Single Socketed Pipes. 2. 110 Mm Diameter, Na Rain Water Spouts and Pipes Providing and Fixing on Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories
for Unplasticised Rigid Pvc Rain Water Pipes Conforming to is 13592 Type a, Including Jointing with Seal Ring Conforming to is 5382, Leaving 10 Mm Gap for Thermal Expansion. 5.2. Bend 87.5° 110 Mm Bend.
|
Value :
INR 41.24 K
*
|
INR 41.24 K
*
|
Due Date :
3 Days to go
|
01/04/2024
|
TID :70802951
Haryana
|
|
|
|
|
|
|
|