1. Sector : Education And Research Institute
Supply of Analytical Balance, Hot Air Oven, Digital Colorimeters, Student Microscopes, Glucometer with Strips for Poct, Thermometer, Semi Autoanalyzer, Boiling Water Baths, Centrifuge, Ph Meters, Fixed and Variable Volume Micro Pipettes, Bottle Dispensers, Pcr Machine, Abg Machine, Complete Chromatographic Unit for Paper and Tlc, Complete Electrophoresis Apparatus with Power Supply, Vortex Mixers, Incubators, Spetrophotometer, Elisa Reader and Washer, Ise Analyzer, Refrigerators, Refrigerators, Spirit Lamp, Glasware and Accessories, Autoanalyser, Waste Bins, Digital Thermometer for Room Temperature and Humidity Check, Consumables, Hplc, Automated Identification and Antimicrobial Susceptibility System, Automated Blood Culture System with Accessories, Metered Dose Inhaler, Spacer and Face Mask, Rotahaler and Rotacaps, Nasal Sprays, Transdermal Patch, Insulin Pen, Samples of Dosage Formulations of Various Types Including Rational and Irrational Fdc Essential Medicines, Chart Models and Videos, Faculty Microscope, 5 Headed Microscope, Students Physographs with Transducers and Other Relevant Accessories, Students Organ Bath with Thermostat, Tissue Aerator, Electroconvulsiometer, Hot and Cold Plate Analgesiometer, Rota Rod Apparatus with Acceration Mode, Animal Weighing Scale, Rat Feeding Gavage Needle, Mice Feeding Gavage Needle, Cooks Pole Climbing Apparatus, Tail Flick Analgesiometer Acto Photometer, Acto Photometer, Soxhlets Apparatus, Electric Heater, Mannequin, Colorimeter Qty 708
|
Value :
INR 6.80 Cr
*
|
INR 68 Mn
*
|
Due Date :
5 Days to go
|
03/04/2024
|
TID :70382367
Assam
|
|
|
|
3. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 5- Pharmacology) (q3) Analgesiometer - Tail Flick (digital), 1 Description of Function, , This Tail Flick Unit is Required to Perform Rapid Precise Screening of Analgesic Drugs on the Rat and, Mice Tail., 2 Operational Requirements, Microprocessor Based System Required with Pc Connectivity, 3 Technical Specifications, , Should Consist of An I.r. Source, Whose Radiant Energy of Adjustable Intensity is Focused on the Rat, Tail., Restrainers Should Be Available to Be Used with Rat and Mice., the Instrument Should Automatically Detect the Withdrawal Latency to the Nearest 0.1 S., the Experimental Data Can Be Directly Exported to the Pc Usb Or Serial Ports., Dedicated Data Acquisition Software Package., 4 Standards, Safety and Training, Manufacturer Should Be Iso 13485 Certified, Calibration/acceptance Test Certificate From the Factory Required., Manufacturer/supplier Should Have Iso Certification for Quality Standards., , Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 5 Documentation, User/service Manual in English ( Both Soft and Hard Copy ) 2 Nos Must Be Provided, Sn Hot Plate Analgesia Meter, 1, Should Be Digitally Controlled and Consist of a Clear Acrylic Chamber/s and Aluminium Plate Providing, Good Temperature Stability and Even Surface Distribution, 2 Operating Temperature Upto 75 Degree Celsius, 3 Digital Display of Temperature Should Be in 0.1 Deg C Increments, 4 Foot Switch to Allow Control of Start and Stop and Permit Hands Free Operation, 5 Should Be Suitable for Both Rats as Well as Mice, 6 Digital Display of Reaction Time in 0.1 Sec Increments., 7 Data Can Be Transferred to Pc Using Usb/ Serial Port., Sn Polygraph (sixteen Channel Research), 1.1 No of Channels 16. It Should Be Able to Use Both for Animals and Humans., 1.2 Ethernet/high Speed Usb Data Acquisition and Analysis Software., 1.3 Apparatus for Recording and Calculating Hrv and Blood Pressure Variability, Temperature, 1.4, Transducers and Softwares for Recording and Analyzing Plethysmography, Gsr, Skin, Temperature, continuous Real-time Beat-to-beat Blood Pressure, Non Invasive Cardiac Out Put, , Respiration, Phonocardiogram and Pulse Tonometer for Carotid Pulse, Baroreflex Sensitivity and Total, Peripheral Resistance Recording., 1.5 21 Inch Tft Monitor, 1.6 1tb Storage Facility, 8gb Ram, I7 Processor, Or Better Configuration Computer, 1.7 Colour Laser Printer, 1.8, Wireless (transmitter / Recorder) Device with Transmit Range Up to 100m, Memory Capacity 480 Hours, , 250 Hz Sampling Rate, Radio Band Frequency, 2 Accessories, Spares and Consumables, 2.1 Necessary Cables and Batteries, 2.2 Computer with Laser Printer to Be Attached to the Equipment, as in Point 1.6 and Point 1.7, 3 Standards, Safety and Training, 3.1 Manufacturer Should Be Iso 13485 Certified, 3.2 Calibration/acceptance Test Certificate From the Factory Required., 3.3 Manufacturer/supplier Should Have Iso Certification for Quality Standards., 3.4, Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 4 Documentation, 4.1 User/service Manual in English, 4.2, Compliance Report to Be Submitted in a Tabulated and Point Wise Manner Clearly Mentioning the, Page/ Para Number of Original Catalogue/data Sheet. Any Point, If Not Substantiated with Authenticated, Catalogue/manual, Will Not Be Considered., 5, Multi Channel Universal Bio-amplifier for Ecg, Emg, Eeg, Eog (at Least 8 Channels) Along with, Cardio Axis Analysis., Sn Electro Convulsiometer, 1 Description of Function, 1.1, to the Study of Anti-convulsion and Anti-epileptic Drugs, Whether for Education, Screening Or, Manufacturing of Drugs, 2 Technical Specifications, 2.1, Should Provide 50hz Stimulus Current Variable From 0.25ma to 330 Ma Through Touch Panel Controls, for Producing Minimal and Supra-maximal Seizure in Small Animals, 2.2 the Duration of Stimulus Current is Variable From 0.1 Second to 9.9 Second in Steps of 0.1 Second, Sn Electro Convulsiometer, Led Indicator for Duration of Stimulus., 2.3 Power Supply 230v 50hz, 2.4 Should Be Supplied with Corneal Electrode Pair (different Cup Size) and Ear Clip 2 Pairs, Should Have Digital Display of Parameters Like Time and Current., 3 Standards, Safety and Training, 3.1 Manufacturer Should Have Iso Certification, 4 Documentation, 4.1 User/technical Manual Should Be Supplied, 5 Experiment Data Exported to Pc Or Dedicated Data Acquisition Software Package., Sn Cooks Pole Climbing Apparatus, 1 Description of Function, 1.1, for Studying Cognitive Function, Mainly Response to Conditioned Stimulus During Learning & Its, Retention, 2 Technical Specifications, 2.1 Digit...
|
Value :
0
*
|
Refer Document
*
|
Due Date :
Closing today
|
29/03/2024
|
TID :70080961
Uttar Pradesh
|
|
|
4. Sector : Non Classified
Drug Administrator Chart
|
Value :
0
*
|
Refer Document
*
|
Due Date :
39 Days to go
|
07/05/2024
|
TID :68362599
Ghana
|
|
|
5. Sector : Non Classified
Drug Testing Supplies
|
Value :
0
*
|
Refer Document
*
|
Due Date :
11 Days to go
|
09/04/2024
|
TID :70226945
United States of America
|
|
|
|
|
|
|
|