1. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 8-bio Chemistry) (q3) the Glassware Should Be Made of High Quality Borosilicate Glass to Withstand High Heat., 2 Apparatus Capacity Should Be of 4 Litres/hr., 3 Should Be Double Stage., 4 Should Have Metallic Stand and Other Accessories., 5 Stand Should Be Made of Rust Free Material., 6 Standards Heating Elements of 2.5-3kw to Be Used., 7 An Automatic Cut Off Device Should Be Attached., 8 Heather Should Be of Quartz for Immediate Output of Distilled Water. Apparatus Should Consist of High, Quality Borosilicate Boiler with Built in Water Leveller., 9 Output Water Should Be Pyrogen-free with Conductivity Less Than 1 Micro Siemen, Ph 6.9-7, Distillate, Temp 65-75 Deg C., 10 Metal Stand., 11 Automatic Cut Off Device Or Safety Control Module., 12 Power Input to Be 220-240 Vac, 50 Hz., 13 Manufacturer Should Be Iso 13485 Certified, Item No. 2, Analytical Balance, I Description of Function, 1 Electronic Balance is Required for Precision Weighing of Lab Samples, Ii Technical Specifications, 1 Weigh Accurately Up to 3rd Decimal Place, 2, Fully Automatic Time and Temperature Controlled Internal Calibration and Balance Should Be, Capable to Adjust Itself, 3 Auto Zero Setting, 4 Weighing Capacity Up to 200g, 5 Readability 0.001g, 6 Repeatability 1mg Or Less, 7 Setting Time - Less Than 2 Seconds, 8 Suitable for Internal/external Adjustment Weights, 9 Pc Connectivity, Iii Balance Should Have, 1 Liquid Crystal Display (lcd) for Display, 2 Ir Sensors for Hands Free Operation, 3 Warns If Balance is Not Correctly Levelled, 4 Automatic/manual and Detachable Draft Shield, 5 Detachable and Adjustable Terminal, 6 Facility for User Administration and Password Protection, 7 Integrated Automatic Safety Function for External Routine Operations, 8 Alphanumeric Data Entry of More Than 2 Ids, 9 Should Be Bis/ Iso Certified and Certificate to Be Provided., Iv Power Supply, 1 Power Input to Be 220-240vac, 50hz, 2 Deleted, 3, Suitable Ups with Maintenance Free Batteries for Minimum One-hour Back-up Should Be, Supplied with the System, 4 Resettable Over Current Breaker Shall Be Fitted for Protection, Item No. 3, Vertical Autoclave, 1 the Vertical Autoclave Should Have Chamber Capacity Of Effective Volume 113 Litres Or More., 2, the Chamber of Vertical Autoclave Should Be Manufactured as Per Asme Standards and, Comply with Pressure Equipment Directive, 3, the Vertical Autoclave Should Work on the Domestic Power Supply of 230 V Ac, 50 Hz, Single, Phase, 4, the Vertical Autocalve's Internal Chamber, Cover Lid and All Wetted Parts Should Be Fabricated, From Stainless Steel of 304 Grade, 5 the Vertical Autoclave Outer Body Should Be of Ss 304., 6 Temperature Range Should Be Up to 135°c and Pressure Up to 30 Psi., 7 the Vertical Autoclave?s All Joints Should Be Smooth Finished for Crevice Free Internals., 8, the Chamber Should Be Hydro Statically Tested at 1.5 Times of Its Working Pressure and, Certificate Should Be Supplied for the Same, 9, the Lid Should Be Equipped with Single Lever Lock Mechanism and Lever Handle Moulded From, Industrial Plastic, 10 the Lid Should Be Provided with Auto Purge Cum Vacuum Breaker Valve and a Manually, Operable Valve for Exhaust., 11 the Unit Should Have a Solenoid Valve for Auto Purging of Air & Normal Exhaust, 12 the Vertical Autoclave Should Have Stainless Steel Pressure Gauge with Dual Range Dial Display, in Kpa and Psi Along with a Co-related Temperature Scale for Steam in Degrees Celsius, 13 the Operations of the Unit Should Be Controlled By Touch Screen Programmable Logic, Controller with 4 Temperature Channels & 1 Pressure Channel Inbuilt., 14 the Autoclave Should Be Equipped with Touch Screen Hmi Plc., 15 Controlling of Chamber Temperature Should Be on All 4 Temperature Channels, 16, to Ensure Proper Sterilization Cycle Autoclave Should Have Facility of Connecting External, Printer Which Can Give Instant Print of All Cycle Data – Customer and Operator Name , Equipment, Number, Recipe, Hold Time, Batch Number, Date & Time, Temperature Set-point, Readings of at, Least Four Temperature Sensors, Pressure Channels F0 Summation and Cycle Status., 17 Inbuilt 6 Recipes for Different Load Should Be Available., 18 Provision of Automatic Water Filling Should Be Available., 19 the Timer Should Be Retentive & Settable Up to 95 Mins, 20, Power Fail Restoration Facility in Case of Power Failure, the Autoclave Should Give Option of, Resuming Cycle with Automatic Adjustment of Sterilization Hold Time, 21 the Unit Should Have Safety Valve to Protect the Equipment in Case of Over Pressurization, 22 the Lid Should Be Equipped with Pressure Interlock Device to Avoid Opening Under Pressure., 23 Lid Should Be Equipped with Door Switch to Avoid Cycle Start If Door is Not Locked Properly., 24 to Ensure Effective Sterilization, If Temperature Falls Below Temperature Set Point the, Sterilization Timer Should Get Automatically Adjusted., 25 the Unit Should Be Provided wit...
|
Value :
0
*
|
Refer Document
*
|
Due Date :
5 Days to go
|
14/05/2024
|
TID :70042369
Uttar Pradesh
|
|
|
|
3. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 2- Forensic Medicine Toxicology) (q3) Down Draft Ventilated Autopsy Table with Integral Sink, Downdraft Ventilated, Stainless Steel, Dissecting Bench, Air Purifier /odour Control System, Cadaver Lift Conveyor Style , Weighing Machine for Dead Bodies, Digital Weighing Machine for Organs/foetus, Oscillating Electric Autopsy Saw (bone Cutting, with Blades), Dissecting Instruments , Cadaver / Autopsy Carrier (non-elevating) , Binocular Microscope (for Students) , Binocular Research Microscope with Camera Attachment , Analytical Balance, Centrifuge Machine, Dissecting Lights (double Ceiling Mounts), Deep Freezer (-40 Deg) , Mortuary Cooler / Refrigerator with Arrangement to Keep 4 Bodies Qty 11
|
Value :
0
*
|
Refer Document
*
|
Due Date :
8 Days to go
|
17/05/2024
|
TID :70065198
Uttar Pradesh
|
|
|
4. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 1- Bio Chemistry) (q3) Agarose Gel Electrophoresis System (horizontal), 1 Gel Electrophoresis System (horizontal) with Power Pack, 2 Horizontal Agarose Gel Electrophoresis Apparatus, 3 Buffer Tank (midi Unit) with Platinum Electrodes, 4 Capacity to Fix Gel with at Least 10 Samples, 5 Gel Casting Tray Standard Form; Combs Sizes 1.0 Mm -10 Wells, 12 Wells, 16 Wells, 24 Wells 2.0 Mm, - 10 Wells, 12 Wells, 16 Wells & 24 Wells, 6 Gel Trays Should Be Uv Transparent, 7 Power Pack – Max, Voltage (300 V), Max Current (500 Ma), Constant Current (available) and Constant, Voltage (available) and at Least Two Outputs, 8 Manufacturer Should Be Iso 13485 Certified, Digital Colorimeters, 1 Fully Automated Digital Photo Diode Based Colorimeter, 2 Colorimeter with 8 Glass Filters Ranging From 400 to 700 Nm, 3 Should Consist of Long Lasting Photo Diode Detector, 4 Should Have Minimum Sample Volume of 1 Ml, 5 Should Have Range of Absorbance 0 to 1.99 and % Transmittance 0 to 100%, 6 Should Have Od Resolution of 0.01, 0.1 % T, 7 Should Have Led Light Source, 8 Should Have Led Display, 9 Should Have Provided with 5 Additional Cuvette and Cuvette Stand/ Case., 10 Should Have Cover with Cuvette Holder., 11 Should Have Dust Protection Cover for the Instrument., 12 Should Have Input 160-260 V and Output 220-240v and 50 Hz, 13 Should Have Provided Battery Backup, 14 Manufacturer Should Be Iso 13485 Certified, Vortex Mixer, 1 Vortex Mixer, Designed with a Heavy Cast Aluminium Body to Provide Optimum Bench-top Stability., 2 the Mixer Has Two Modes of Operation Continuous Operation When You Need to Mix a Quantity of, Tubes in Sequence; Intermittent Operation is Activated By Touching the Cup Attachment with a Test Tube., 3 Equipped with a Single Tube Mixing Cup for Single Tube Mixing and a Soft Foam Pad and Mixing, Platform for Mixing 1-4 Test Tubes Simultaneously., Vortex Mixer, 4 to Be Supplied with a Fractional Workable Motor on 220v Ac Completed with Indicator, Plug & Cord, , Speed 100-3000 Rpm, Dimensions (lxwxh) - 17.7x11.4x15.2 Cms., 5 Manufacturer Should Be Iso 13485 Certified, Densitometer with Computer (gel), 1, Computer Controlled Chemiluminescence Western Blot, Trans-uv for Dna, Rna Gel and Colorimetric, Protein Gel Imaging System with Extensive Analysis Tool for Molecular Weight Calculation, Band, Distance, Colony Counting, Etc., 2 System Must Allow for Future Upgrade for Fluorescence Based Imaging and Multiplexing Application, with the Choice of Uv, Visible (red, Green, Blue), Near Ir, Ir and Deep Ir Spectral Excitation., 3 Scientific Grade Ccd Camera with High Sensitivity and Extremely High Level of Resolution, 4 Camera Should Give 6 Megapixels Or More Image Resolution, 5 Camera Must Be a Cooled Ccd with -50°c Maximum Differential Cooling From the Ambient with -25°c, Absolute and Regulated Cooling By Three Stage Peltier Thermoelectric Cooler., 6 Interface Must Be Usb 3.0 for Faster Image Transfer to Help Image Before Signal Gets Weaker., 7 Should Be a Lab Proof Compact Design, Require Minimal Bench Space, Robust and Chemical Resistant, System Made of Stainless Steel, Aluminum Or Steel, 8 Technology to Visualize Faint Bands Thereby Increased Sensitivity with No Visible Light Background, While Performing Gel Documentation, 9 High Sensitivity Reading Technology for Isolation of the Electronic Components of the Camera During the, Light Capture in Order to Avoid Noise, 10 Should Have Smart Auto Exposure Mode with Optimum Exposure Time Calculation By the Software, Based on the Signal Output From the Sample, 11 Software Should Provide Options for 1x1, 2x2, 3x3, 4x4 Binning., 12 4-position Filter Wheel Allows for Dye Flexibility of Different Fluorescent Stains., 13 Pre-calibrated Focus for All Defined Sample Height. Easy and Convenient Adjustment of Lens Settings, Fluorescent Microscope, 1 Microscope Body Microscope with Infinity Optical Corrected Optical System with Light Path Selector of, 1000, 0100., 2 Eyepiece 10x (paired) with F O V 22mm and Diopter Adjustment Facilities on Both Eyes, Anti-fungus, Type., 3 Condenser Extra Long Working Condenser (suitable for Phase Contrast/bf/fluorescence), 4 Illumination Pre Centred Mercury Fibre Illuminator of 130w/metal Halide Illuminator of 120/130w with, Facility for No Heat Lifetime of 2000 Hrs Or More, 5 Nosepiece Quintuple Nosepiece to Accommodate 5 Objectives at a Time., Fluorescent Microscope, 6 Stage Attachable Mechanical Stage with Universal Holder to Accept All Types of Specimen Holders., 7 Objectives 4x (n.a.0, 10, W.d 30.0mm Or Higher), 10x (n.a 0.25, W.d 5.2 Mm), 20x (n.a, 0.45, W.d, , 8.2-6.9mm), 40x(n.a.0.60, W.d, 3.6-2.8mm), 8, Epi-fluorescence Attachment Noise Terminator Mechanism Incorporated for High Signal Ratio Images, with Pre Centred Mercury Fibre Illuminator of 130w. Main Body Must Hold 4-6 Fluorescence Filter Block, and One Empty Position for Bright Field. Epi-fluor Filter Block (blue) Consisting ...
|
Value :
0
*
|
Refer Document
*
|
Due Date :
8 Days to go
|
17/05/2024
|
TID :70067420
Uttar Pradesh
|
|
|
|
6. Sector : Education And Research Institute
Supply of Thermal expansion app Digital, Annealing testing app For glass Strain viewer, Diamond cutter with variable diameter of blade 8 Inch, 10 Inch, 12 inch, Under Load refractory testing furnance, Motorised Drill Machine with Diaomond bits with 5 to 10 mm dia Ultrasonic Drilling for glass Machine Motorised drilling machiner, Ultra Voilet Glass Viewer, Digital apparatus For flue gas analysis, Piling resistance test app, Softening point app With accessories, Weighing Balance, Rockwell hardness tester with computer programming or Digital, Universal MOR Machine For Mechanical Strength of Ceramic Rod Testing, Grinding Polishing Machines for sample preparation, Pot Mill, Ball Mill for Glaze Lab Size, Digital Cold Crushing machine, De- airing pug mill Lab Size, Hot Plate, Mohs Scale for hardness, Ultrasonic Drilling for glass Machine Motorised drilling machiner, Platinum Crucible with lid 25 ml, Platinum dish with lid 10 cm dia, Hydro Flourication Ohamber, Digital Electronics Balance - Glass Ceramic Lab ExistP Qty 31
|
Value :
0
*
|
Refer Document
*
|
Due Date :
1 Day to go
|
10/05/2024
|
TID :70382206
Uttar Pradesh
|
|
|
7. Sector : Education And Research Institute
Supply of Analytical Balance, Hot Air Oven, Digital Colorimeters, Student Microscopes, Glucometer with Strips for Poct, Thermometer, Semi Autoanalyzer, Boiling Water Baths, Centrifuge, Ph Meters, Fixed and Variable Volume Micro Pipettes, Bottle Dispensers, Pcr Machine, Abg Machine, Complete Chromatographic Unit for Paper and Tlc, Complete Electrophoresis Apparatus with Power Supply, Vortex Mixers, Incubators, Spetrophotometer, Elisa Reader and Washer, Ise Analyzer, Refrigerators, Refrigerators, Spirit Lamp, Glasware and Accessories, Autoanalyser, Waste Bins, Digital Thermometer for Room Temperature and Humidity Check, Consumables, Hplc, Automated Identification and Antimicrobial Susceptibility System, Automated Blood Culture System with Accessories, Metered Dose Inhaler, Spacer and Face Mask, Rotahaler and Rotacaps, Nasal Sprays, Transdermal Patch, Insulin Pen, Samples of Dosage Formulations of Various Types Including Rational and Irrational Fdc Essential Medicines, Chart Models and Videos, Faculty Microscope, 5 Headed Microscope, Students Physographs with Transducers and Other Relevant Accessories, Students Organ Bath with Thermostat, Tissue Aerator, Electroconvulsiometer, Hot and Cold Plate Analgesiometer, Rota Rod Apparatus with Acceration Mode, Animal Weighing Scale, Rat Feeding Gavage Needle, Mice Feeding Gavage Needle, Cooks Pole Climbing Apparatus, Tail Flick Analgesiometer Acto Photometer, Acto Photometer, Soxhlets Apparatus, Electric Heater, Mannequin, Colorimeter Qty 708
|
Value :
0
*
|
Refer Document
*
|
Due Date :
1 Day to go
|
10/05/2024
|
TID :70382367
Assam
|
|
|
8. Sector : Education And Research Institute
Supply of Items, High Speed Attritor , Bead Mill 1 Litre with Motar , Pestle, and Mortor , Lab Stirrer High Speed , Digital Electronic, Balance , Spectrophotometer , Specific Gravity Bottle , , Refractometers , Pipette , Burette , Concial Flask , Glass, Plate 4 Cm Diameter , Hot Oven , Pipette 25 Ml , Burette, 50ml , Digital Electronics Balance , Spatula Steel , Glass, Plate 6x6 Inch , Iron Plate 6x6 Inch , Filter Paper , , Condenser with Tube and Heating Material , Test Tube Stand, , Funnel Stand , Burrete Stand , Pipette Stand , Reagents, Bottle 250ml, 500ml, 1000ml , Measuring Flask 250ml with, Stopper , Measuring Cylinder for Various Size 250ml, 500ml, , 1000 Ml , Sprit Lamp , Brush Small for Cleaning Various Type, of Material , Ph Meter , Hot Plate , Stirrer with Speed, Regulator with , Three Neck Flask , Stirrer Rod , Stirrer Blade, Teflon , Colorimeter Digital , Weight Per Litre Cup , Hegman, Gauge , Viscometer Brookfield , Glass Plate Petri Dish , B K, Drying Recorder Digital , Dft Gauge , Cylindrical Mandrel , , Conical Mandrel , Pencil Hardness Tester with Pencil Like, 1h, 2h, hb Etc Set , Impact Tester , Glossometer , Humidity, Chamber , Salt Spray Chamber , Ford Cup No.4 with Spatula, , Checker Board , Cross Cut Adhesion Tester , Scratch, Hardness Tester , Spray Booth , Spray Gun , Metal Panels, 100 Pcs , Cylindrical Flask of 1 Lit , High Speed Stirrer , China, Clay Pot and Stirrer , Lab Bead Ball Mill with Motor , Iron Rod, , Brush for Mixing and Cleaning , Lab Table 2mx1.2mx1m, Height with Central Sink and Cup Boards Teak Wood with, Drawers and Two Built in Almirah on Each Side with Reagents, Rack , Better Tile Top , Distilled Water Unit Electrical , Jar 20, Lit . for Keeping Distilled Water , Exhaust Fan 18inch , , Autometic Pigment Muller Qty 245
|
Value :
0
*
|
Refer Document
*
|
Due Date :
1 Day to go
|
10/05/2024
|
TID :70490890
Uttar Pradesh
|
|
|
|
|