|
|
|
|
|
6. Sector : Health Services/Equipments
Procurement of “skullbase Surgery Set Straightforward Telescope 0°, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated., Forward-oblique Telescope 30°, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light, Transmission Incorporated., Straight Forward Telescope with Straight Eye Peice of Scope, Diameter 4 Mm, Length 18 Cm, Autoclavable, Angle of View - 15 Or 20 Or 30 Degree, Angle of View - 45 Degree, Angle of View - 70 Degree, Angle of View - 90 Degree, Or Single Telescope Diameter 4mm Length 18cm with Variable Direction of View From 15 Degree to 90degree, Adjustment Knob for Selecting the Desired Direction of View, Fiber Optic Light Transmission Incorporated, , Irrigation and Suction Sheath, Outer Diameter 4.8 X 6 Mm, Working Length 14 Cm, for Use Will Variable Angle of View Scope., Straight Forward Telescope 0° with Enlarged View. Scope Diameter4 Mm, Length 18-19 Cm, Scope Should Be Autoclavable with Fiber Optic Light Transmission Incorporated. Scope Should Be Compitable with White Light and Icg Light, Straight Forward Telescope 30° with Enlarged View. Scope Diameter4 Mm, Length 18-19 Cm, Scope Should Be Autoclavable with Fiber Optic Light Transmission Incorporated. Scope Should Be Compitable with White Light and Icg Light, Nasal Scissors, Medium Size Working Length 9-10 Cm, Cuptuitar/nucleus Cutting Forceps Single Action Jaws, Movable Jaw Opening Upwards, Ter 3- 4 Mm, Working Length 18-20 Cm, Forceps Straight, Upturned, Size 1, with Cleaning Connector, Working Length 11-13 Cm, Forceps, 45° Uptumed, Size 1, with Cleaning Connector, Working Length 11-13 Cm, Knife, Pointed, Length 18-20 Cm, Scissors, Straight, with Small Handle, with Cleaning Connector, Working Length 18-20cm, Scissors, Curved to Right, with Small Handle, with Cleaning Connector, Working Length 18-20 Cm, Scissors, Curved to Left, with Small Handle, with Cleaning Connector, Working Length 18-20 Cm, Scissors, Curved Upwards, with Small Handle, with Cleaning Connector, Working Length 18-20 Cm, Scissors, Uptumed 45°, Delicate Sheath 360 Rotatable , with Cleaning Connector, Working Length 18-20 Cm, Curette Round Spoon, Tip Slightly Angled, Size 1-3 Mm with Round Handle, Length 23-25 Cm, Curette Round Spoon Tip Slightly Angled, Size 2-4 Mm, with Round Handle, Length 23-25 Cm, Ring-curette, Round Wire, Id 2-5-3-5 Mm, Tip Angled 45°, with Round Handle, Length 23-25 Cm, Ring-curette Round Wire, Id 2-5 Mm, Tip Angled 45°, with Round Handle, Length 23-25 Cm, Ring-curette, Round Wire, Id 2-4 Mm Tip Laterally Angled 90°, with Round Handle, Length 23-25 Cm, Bone Punch, Detachable , Rigid, Upbiting 60° Forward, Size 1 Mm, Working Length 15-17 Cm, Bone Punch, Detachable, Rigid, Downbiting 60° Forward, Size 2 Mm, Working Length 15-17 Cm, Bone Punch Detachable Rigid, Downbitng 60° Forward, Size 1 Mm, Working Length 15-17 Cm, Bone Punch Detachable Rigid, Downbiting 60° Forward, Size 3 Mm, Working Length 15-17 Cm, Nasal Forceps, with Extra Fine Falt Jaws, Through-cutting, Tissue Sparing, Width of Cut 1-2 Mm, Straight Sheath, Straight Jaws, with Cleaning Connector, Working Length 16-18 Cm, Nasal Forceps, with Extra Fine Falt Jaws, Through-cutting, Tissue Sparing, Width of Cut 1-2 Mm, Straight Sheath, Straight Jaws, Angled Upwards 45 Degree with Cleaning Connector, Working Length 16-18 Cm, Backbiter, Backward Cutting , Cross-toothed, Cutting Width 3-4 Mm, Straight Jaws, Sheath Diameter 2.5-3.5 Mm, Straight, Handle with Cleaning Connector, Working Length 10-14 Cm, Bipolar High Frequency Cord, Length 290-300 Cm, , Double Prong Bipolar Forceps, Straight Jaws with Rounded Tip, Jaws Width 1.9.2 Mm, Sheath Outer Diameter 3.2-3.4 Mm Working Length 18-20 Cm, Bipolar Should Come in 4 Parts Handle, Inner Tube, Outer Tube and Bipolar Insert Tip, Bipolar Grasping Forceps, Tip Size 0.8-1mm Jaw Angled 45 Degree, Outer Sheath Size 3 to 3.5mm, Length 18-20 Cm, Bipolar Should Come in 4 Parts Handle Inner Tube, Outer Tube and Bipolar Insert Tip., Bipolar Forcep Additional Insert Only 3 Different Tips, Plastic Container for Sterilization, Especially Suited for Hydrogen Peroxide Sterilization and Storage, Perforated Wit Lid, External Dimensions (w X D X H)425-450x80-100x40-50 Mm, for Use with Two Rigid Endoscopes Up to Max. 32 Cm Working Length, Plastic Container for Sterilization, Especially Suited for Hydrogen Peroxide Sterilization and Storage, Perforated with Lid, External Dimensions (w X D X H)310-330x80-100x40-50 Mm, for Use with Two Rigid Endoscopes Up to Max. 20 Cm Working Length`, Instrument Tray, Plastic Container for Sterilization and Storage of Variable Instrument, Container Should Be with Silicone Mat and Two- Level Storage. Container Should Be Perforated with Transparent Lid. Container Should Be with Silicon Mat and Two-level Storage. External Minimum Dimensions (w X D X H) 545x260x115 Mm. the Plastic Container Should Be Suitable for Steam, Gas and Hydrogen Peroxide Sterilization.
|
Value :
0
*
|
Refer Document
*
|
Due Date :
Closing today
|
18/04/2024
|
TID :69511372
Jammu-kashmir
|
|
|
7. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 8-bio Chemistry) (q3) the Glassware Should Be Made of High Quality Borosilicate Glass to Withstand High Heat., 2 Apparatus Capacity Should Be of 4 Litres/hr., 3 Should Be Double Stage., 4 Should Have Metallic Stand and Other Accessories., 5 Stand Should Be Made of Rust Free Material., 6 Standards Heating Elements of 2.5-3kw to Be Used., 7 An Automatic Cut Off Device Should Be Attached., 8 Heather Should Be of Quartz for Immediate Output of Distilled Water. Apparatus Should Consist of High, Quality Borosilicate Boiler with Built in Water Leveller., 9 Output Water Should Be Pyrogen-free with Conductivity Less Than 1 Micro Siemen, Ph 6.9-7, Distillate, Temp 65-75 Deg C., 10 Metal Stand., 11 Automatic Cut Off Device Or Safety Control Module., 12 Power Input to Be 220-240 Vac, 50 Hz., 13 Manufacturer Should Be Iso 13485 Certified, Item No. 2, Analytical Balance, I Description of Function, 1 Electronic Balance is Required for Precision Weighing of Lab Samples, Ii Technical Specifications, 1 Weigh Accurately Up to 3rd Decimal Place, 2, Fully Automatic Time and Temperature Controlled Internal Calibration and Balance Should Be, Capable to Adjust Itself, 3 Auto Zero Setting, 4 Weighing Capacity Up to 200g, 5 Readability 0.001g, 6 Repeatability 1mg Or Less, 7 Setting Time - Less Than 2 Seconds, 8 Suitable for Internal/external Adjustment Weights, 9 Pc Connectivity, Iii Balance Should Have, 1 Liquid Crystal Display (lcd) for Display, 2 Ir Sensors for Hands Free Operation, 3 Warns If Balance is Not Correctly Levelled, 4 Automatic/manual and Detachable Draft Shield, 5 Detachable and Adjustable Terminal, 6 Facility for User Administration and Password Protection, 7 Integrated Automatic Safety Function for External Routine Operations, 8 Alphanumeric Data Entry of More Than 2 Ids, 9 Should Be Bis/ Iso Certified and Certificate to Be Provided., Iv Power Supply, 1 Power Input to Be 220-240vac, 50hz, 2 Deleted, 3, Suitable Ups with Maintenance Free Batteries for Minimum One-hour Back-up Should Be, Supplied with the System, 4 Resettable Over Current Breaker Shall Be Fitted for Protection, Item No. 3, Vertical Autoclave, 1 the Vertical Autoclave Should Have Chamber Capacity Of Effective Volume 113 Litres Or More., 2, the Chamber of Vertical Autoclave Should Be Manufactured as Per Asme Standards and, Comply with Pressure Equipment Directive, 3, the Vertical Autoclave Should Work on the Domestic Power Supply of 230 V Ac, 50 Hz, Single, Phase, 4, the Vertical Autocalve's Internal Chamber, Cover Lid and All Wetted Parts Should Be Fabricated, From Stainless Steel of 304 Grade, 5 the Vertical Autoclave Outer Body Should Be of Ss 304., 6 Temperature Range Should Be Up to 135°c and Pressure Up to 30 Psi., 7 the Vertical Autoclave?s All Joints Should Be Smooth Finished for Crevice Free Internals., 8, the Chamber Should Be Hydro Statically Tested at 1.5 Times of Its Working Pressure and, Certificate Should Be Supplied for the Same, 9, the Lid Should Be Equipped with Single Lever Lock Mechanism and Lever Handle Moulded From, Industrial Plastic, 10 the Lid Should Be Provided with Auto Purge Cum Vacuum Breaker Valve and a Manually, Operable Valve for Exhaust., 11 the Unit Should Have a Solenoid Valve for Auto Purging of Air & Normal Exhaust, 12 the Vertical Autoclave Should Have Stainless Steel Pressure Gauge with Dual Range Dial Display, in Kpa and Psi Along with a Co-related Temperature Scale for Steam in Degrees Celsius, 13 the Operations of the Unit Should Be Controlled By Touch Screen Programmable Logic, Controller with 4 Temperature Channels & 1 Pressure Channel Inbuilt., 14 the Autoclave Should Be Equipped with Touch Screen Hmi Plc., 15 Controlling of Chamber Temperature Should Be on All 4 Temperature Channels, 16, to Ensure Proper Sterilization Cycle Autoclave Should Have Facility of Connecting External, Printer Which Can Give Instant Print of All Cycle Data – Customer and Operator Name , Equipment, Number, Recipe, Hold Time, Batch Number, Date & Time, Temperature Set-point, Readings of at, Least Four Temperature Sensors, Pressure Channels F0 Summation and Cycle Status., 17 Inbuilt 6 Recipes for Different Load Should Be Available., 18 Provision of Automatic Water Filling Should Be Available., 19 the Timer Should Be Retentive & Settable Up to 95 Mins, 20, Power Fail Restoration Facility in Case of Power Failure, the Autoclave Should Give Option of, Resuming Cycle with Automatic Adjustment of Sterilization Hold Time, 21 the Unit Should Have Safety Valve to Protect the Equipment in Case of Over Pressurization, 22 the Lid Should Be Equipped with Pressure Interlock Device to Avoid Opening Under Pressure., 23 Lid Should Be Equipped with Door Switch to Avoid Cycle Start If Door is Not Locked Properly., 24 to Ensure Effective Sterilization, If Temperature Falls Below Temperature Set Point the, Sterilization Timer Should Get Automatically Adjusted., 25 the Unit Should Be Provided wit...
|
Value :
0
*
|
Refer Document
*
|
Due Date :
12 Days to go
|
30/04/2024
|
TID :70042369
Uttar Pradesh
|
|
|
8. Sector : Health Services/Equipments
Supply of Group Tender for Various Medical Equipment (g 5- Pharmacology) (q3) Analgesiometer - Tail Flick (digital), 1 Description of Function, , This Tail Flick Unit is Required to Perform Rapid Precise Screening of Analgesic Drugs on the Rat and, Mice Tail., 2 Operational Requirements, Microprocessor Based System Required with Pc Connectivity, 3 Technical Specifications, , Should Consist of An I.r. Source, Whose Radiant Energy of Adjustable Intensity is Focused on the Rat, Tail., Restrainers Should Be Available to Be Used with Rat and Mice., the Instrument Should Automatically Detect the Withdrawal Latency to the Nearest 0.1 S., the Experimental Data Can Be Directly Exported to the Pc Usb Or Serial Ports., Dedicated Data Acquisition Software Package., 4 Standards, Safety and Training, Manufacturer Should Be Iso 13485 Certified, Calibration/acceptance Test Certificate From the Factory Required., Manufacturer/supplier Should Have Iso Certification for Quality Standards., , Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 5 Documentation, User/service Manual in English ( Both Soft and Hard Copy ) 2 Nos Must Be Provided, Sn Hot Plate Analgesia Meter, 1, Should Be Digitally Controlled and Consist of a Clear Acrylic Chamber/s and Aluminium Plate Providing, Good Temperature Stability and Even Surface Distribution, 2 Operating Temperature Upto 75 Degree Celsius, 3 Digital Display of Temperature Should Be in 0.1 Deg C Increments, 4 Foot Switch to Allow Control of Start and Stop and Permit Hands Free Operation, 5 Should Be Suitable for Both Rats as Well as Mice, 6 Digital Display of Reaction Time in 0.1 Sec Increments., 7 Data Can Be Transferred to Pc Using Usb/ Serial Port., Sn Polygraph (sixteen Channel Research), 1.1 No of Channels 16. It Should Be Able to Use Both for Animals and Humans., 1.2 Ethernet/high Speed Usb Data Acquisition and Analysis Software., 1.3 Apparatus for Recording and Calculating Hrv and Blood Pressure Variability, Temperature, 1.4, Transducers and Softwares for Recording and Analyzing Plethysmography, Gsr, Skin, Temperature, continuous Real-time Beat-to-beat Blood Pressure, Non Invasive Cardiac Out Put, , Respiration, Phonocardiogram and Pulse Tonometer for Carotid Pulse, Baroreflex Sensitivity and Total, Peripheral Resistance Recording., 1.5 21 Inch Tft Monitor, 1.6 1tb Storage Facility, 8gb Ram, I7 Processor, Or Better Configuration Computer, 1.7 Colour Laser Printer, 1.8, Wireless (transmitter / Recorder) Device with Transmit Range Up to 100m, Memory Capacity 480 Hours, , 250 Hz Sampling Rate, Radio Band Frequency, 2 Accessories, Spares and Consumables, 2.1 Necessary Cables and Batteries, 2.2 Computer with Laser Printer to Be Attached to the Equipment, as in Point 1.6 and Point 1.7, 3 Standards, Safety and Training, 3.1 Manufacturer Should Be Iso 13485 Certified, 3.2 Calibration/acceptance Test Certificate From the Factory Required., 3.3 Manufacturer/supplier Should Have Iso Certification for Quality Standards., 3.4, Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 4 Documentation, 4.1 User/service Manual in English, 4.2, Compliance Report to Be Submitted in a Tabulated and Point Wise Manner Clearly Mentioning the, Page/ Para Number of Original Catalogue/data Sheet. Any Point, If Not Substantiated with Authenticated, Catalogue/manual, Will Not Be Considered., 5, Multi Channel Universal Bio-amplifier for Ecg, Emg, Eeg, Eog (at Least 8 Channels) Along with, Cardio Axis Analysis., Sn Electro Convulsiometer, 1 Description of Function, 1.1, to the Study of Anti-convulsion and Anti-epileptic Drugs, Whether for Education, Screening Or, Manufacturing of Drugs, 2 Technical Specifications, 2.1, Should Provide 50hz Stimulus Current Variable From 0.25ma to 330 Ma Through Touch Panel Controls, for Producing Minimal and Supra-maximal Seizure in Small Animals, 2.2 the Duration of Stimulus Current is Variable From 0.1 Second to 9.9 Second in Steps of 0.1 Second, Sn Electro Convulsiometer, Led Indicator for Duration of Stimulus., 2.3 Power Supply 230v 50hz, 2.4 Should Be Supplied with Corneal Electrode Pair (different Cup Size) and Ear Clip 2 Pairs, Should Have Digital Display of Parameters Like Time and Current., 3 Standards, Safety and Training, 3.1 Manufacturer Should Have Iso Certification, 4 Documentation, 4.1 User/technical Manual Should Be Supplied, 5 Experiment Data Exported to Pc Or Dedicated Data Acquisition Software Package., Sn Cooks Pole Climbing Apparatus, 1 Description of Function, 1.1, for Studying Cognitive Function, Mainly Response to Conditioned Stimulus During Learning & Its, Retention, 2 Technical Specifications, 2.1 Digit...
|
Value :
0
*
|
Refer Document
*
|
Due Date :
4 Days to go
|
22/04/2024
|
TID :70080961
Uttar Pradesh
|
|
|
|