Ref. Number : 37087056 Tender Number : 2019_NHPC_509167_1 Tender Prod. No : 2019_NHPC_509167_1
Requirement : Supply, installation, testing and commissioning of electrical items for implementation of disaster management plan in power house 415v ac lv panel; indoor type semi-compartmentalized; crca sheet alongwith 02 nos. 2000a acb as main incomer & 2000a 3p+n cu busbar as per drawing & technical specification confirming to relevant is., 415v ac lv panel; indoor type; semi-compartmentalized; crca sheet alongwith 01 no. 2000a acb as main incomer, 2000a 3p+n cu busbar & outgoing switchgears (outgoers 4 nos. - 320 a & 3 nos. - 63a) as per drawing & technical specification confirming to relevant is., 415v, 320a,3p+n mccb as main incommer ac distribution board alongwith 3p+n cu busbar & 12 way 4 pole mcb distribution (outgoers 5 nos. - 63 a & 5 nos. - 32a with 4 pole 63a/32a mcb ) ; indoor type; crca sheet fully enclosed type as per drawing & technical specification confirming to relevant is., 415v, 63a, 3p+n mccb as main incommer ac distribution board alongwith 3p+n cu busbar & 12 way single pole mcb distribution & 6 -10 a, 230v, single pole mcb ; indoor type; crca sheet fully enclosed type as per drawing & technical specification confirming to relevant is., dry-type transformer, 1 mva, 3-ph, 0.4/11 kv, 50 hz, along with cubicles & complete with all required accessories, control & protection. (configuration as per technical specification), dry-type transformer, 1 mva, 3-ph, 11/0.4 kv, 50 hz, along with cubicles & complete with all required accessories, control & protection. (configuration as per technical specification), vacuum circuit breaker (vcb), 630 amp, 11 kv, 3 pole, 50 hz, along with cubicles & complete with all required accessories, control & protection. (configuration as per technical specification), 3 core, 35 sq.mm., 11 kv, frls, xlpe insulated, aluminium conductor armoured ht cable , single core, 95 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor armoured lt cable., 4 core, 70 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor armoured lt cable., 3.5 core, 16 sq.mm., 1.1 kv, frls, xlpe insulated, aluminium conductor armoured lt cable., 3.5 core, 10 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor lt cable., 2.5 core, 2.5 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor lt cable., single core, 16 sq.mm., 1.1 kv, frls, pvc insulated (green), copper conductor unarmoured flexible earth cable., xlpe indoor termination kit for 35 sq.mm. 3 core 11 kv ht cable (cold sealing type), 32 amp, 3 phase, 415 volt, 5 pin (3p+n+e), ip65, industrial type socket outlet with wall mount enclosure & 4p mcb of same rating, 63 amp, 3 phase, 415 volt, 5 pin (3p+n+e), ip65, industrial type socket outlet with wall mount enclosure & 4p mcb of same rating, 100 w led, industrial waterproof ip66 flood light fitting complete with led lamps & all accessories., cable tray; ladder type (ms g.i. sheet - minimum 2.00mm thick); size 400x50mm, cable tray; ladder type (ms g.i. sheet - minimum 2.00mm thick); size 200x50mm, gi angle iron clamps of size 50x50x5mm for cable trays, stainless steel cable ties of size 100-300mm ( 01 packet containing 100 nos. cable ties), cable lugs, 35 sq.mm.,tubular type aluminium, cable lugs, 95 sq.mm.,tubular type copper, cable lugs, 16 sq.mm.,tubular type aluminium, cable lugs, 16 sq.mm.,tubular type copper, nickel plated brass cable glands (heavy duty) flameproof size 44.5 mm dia, nickel plated brass cable glands (heavy duty) flameproof size 23 mm dia, nickel plated brass cable glands (heavy duty) flameproof size 32 mm dia, nickel plated brass cable glands (heavy duty) flameproof size 21 mm dia, nickel plated brass cable glands (heavy duty) flameproof size 17 mm dia, erection, testing & commissioning of dry-type x'mers along with connections to ht/lt cables, erection, testing & commissioning of lt panels, erection, testing & commissioning of vcb panel, installation of 2 no.main distribution board along with all connections & testing., laying of 3 core, 35 sq.mm., 11 kv, frls, xlpe insulated, aluminium conductor armoured ht cable, laying of lt cables single core, 95 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor armoured lt cable., laying of lt cables 4 core, 70 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor armoured lt cable., laying of lt cables 3.5 core, 16 sq.mm, 1.1 kv, frls, xlpe insulated, aluminium conductor armoured lt cable., laying of lt cables 3.5 core, 10 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor lt cable., laying of lt cables 2.5 core, 2.5 sq.mm., 1.1 kv, frls, xlpe insulated, copper conductor lt cable., laying of single core, 16 sq.mm., 1.1 kv, frls, pvc insulated (green), copper conductor unarmoured flexible earth cable., installation of led flood lights along with connections from mcb db to fittings., installation of 63/32 amps industrial type socket outlet along with all connections, installation of cable trays with angle iron clamp support for ladder type cable tray, installation of cable termination / jointing kits.

Key Values

Document Fees : 1,680
EMD : 486,000
Tender Estimated Cost : 24,271,130
Closing Date : 12/12/2019
Document Sale To : 18/11/2019
Location : Jammu-kashmir - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert
Help Desk
To know more about any Tender Assistance, please contact :

+91-9328913635 / sales@TenderTiger.com OR
"Click Here, we shall get back to you"

To know more about any Digital Certificate kindly Click Here

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.