Tender Detail

Buyer/Seller : Can be viewed by Subscribers
Ref. Number : 43618264 Tender Number : 40/CSC (2020-21) Tender Prod. No : 40/CSC (2020-21)
Requirement : Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard laterite as per enclosed specifications.
Supply of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard lateriteas per enclosed specifications.
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as per specifications.
Supply of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches conforming to International Standards and complete with Fault Passage Indicator other accessories as per specifications.
Supply of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets, lugs, connectors etc. (for 11KV take off gantry at 33 by 11KV sub station and for interlinking with other 11KV Overhead feeders).
Supply of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets,lugs, connectors etc. for connecting RMU for main section side.
Supply of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets,lugs,connectors etc. for connecting 11KV end of Distribution transformer.
Supply of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets,lugs,connectors etc. for connecting RMU for main section side.
Supply of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets,lugs,connectors etc.
Supply of Cable route Markers (for entire 11 KV cable route length ) as per NIT drawing.
Supply and Erection of Warning tape for entire 11 KV route length.
Supply and laying of fine river sand of approved quality for cushioning of HT underground cables laid by conventional Open Trenching Method.
Providing and laying of RCC protective covers of size 600mm long x 250mm width and 50mm thick capable of bearing load of 135 kgs And covered with earth, sand upto a depth of 0.15mtr Confirming to IS 1256-1967 at non road crossing.
Supply and laying of wire cut Bricks for 11KV Cable seperation.
Supply of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMUs The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand, soil with Brick masonary Chambers The work includes excavation, backfilling and spreading of excavated surplace earth evenly at RMUs.
Supply of HDGI flat of size 25mm x 5mm for earthing of RMUs.
Providing and laying in position cement concrete 124 (1 cement 2 coarse sand 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations of RMUs).
Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete for RMUs.
12 mm cement plaster 14 ( 1 cement 4 fine sand) for foundations of RMUs.
Supply of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.
Supply of GI pipe,150mm dia for bridge crossing.
Laying of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S.
Laying of 11KV, 3 core 185sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK through conventional open trenching method in any type of soil including hard lateriteas per enclosed specifications.
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with two Load Break Switches and one Circuit Breaker conforming to International Standards and complete with Fault Passage Indicator other accessories as per specifications.
Erection of 11KV, 630 Amps, Outdoor, SF6 Ring Main Unit with three Load Break Switches conforming to International Standards and complete with Fault Passage Indicator other accessories as per specifications.
Erection of 11KV, 3 phase, Outdoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300sq.mm including sockets, lugs, connectors etc. (for 11KV take off gantry at 33 by 11KV sub station and for interlinking with other 11KV Overhead feeders).
Erection of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets,lugs, connectors etc. for connecting RMU for main section side.
Erection of 11KV 3 phase outdoor terminating kit complete, for 11 KV XLPE cable of size 3 x 185 sq.mm including sockets,lugs,connectors etc. for connecting 11KV end of Distribution transformer.
Erection of Cable route Markers (for entire 11 KV cable route length ) as per NIT drawing.
Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator) or manual means for laying of HT, LT cables of various sizes including excavation for equipment foundations i.e for RMUs including getting out the excavated soil and disposal of surplus excavated soil.
Refilling of excavated soil in the foundations, trenches etc. with avialable excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments.
Erection of G.I. earthing pipe, 2500mm long, 40mm nominal dia, class B, perforated for RMUs The pit shall be filled with homogenous mixture of 20Kgs of Charcoal, 20Kgs of salt and sand, soil with Brick masonary Chambers The work includes excavation, backfilling and spreading of excavated surplace earth evenly at RMUs.
Erection of HDGI flat of size 25mm x 5mm for earthing of RMUs.
Laying of RCC Hume Pipe 150mm dia with required no. of collars, for road crossing.
Laying of GI pipe,150mm dia for bridge crossing.
Carrying out detailed physical survey of the area including detailed GPS survey which includes indicating and marking location of other utilities if any, furnishing of optimum and economical route and design for layong of LT, XLPE cables of various size and accessories, including plotting on the scaled land base map of size 11000 indicating all features and submitting drilling profile indicating proposed plan for open trenching,road,nullah,culvet, over bridge, rail crossing, or any other special crossing. The work shall include digging of trial pits at suitable intervals and reinstatement of dug-up area of trial pits. The detailed documents as well as the write-up shall be furnished in 02 nos. of hard copies and soft copies for approval.Upon approval fresh 06 Nos. of hard copies alongwith a soft copy shall be furnished duly corrected. On completion, the contractor has to submit final survey map with longitude and latitude of each every item with other details for asset mapping.

Key Values

Document Fees : INR 1,500
EMD : INR 2,000,000
Tender Estimated Cost : INR 104,984,965
Closing Date : 6/05/2021
Location : Goa - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Tender Documents