Requirement :
|
Construction, testing and commissioning of RCC elevated service reservoir of 40 kl capacities & staging 12 mt. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber, construction of 25 k.l. r.c.c. sump well, & providing, laying, jointing, interconnection, testing and commissioning of 90,110 mm dia pvc class 6kg/sqcm, 90 mm dia pvc class 10 kg/sqcm with suitable joints & 100 mm dia gi pipe, valve specials and all fittings including all allied civil works , supplying & installation of energy efficiant five star bee rating isi marked required capacity single phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe,ss/nylon wire ropeand connection cable including verification of tubewell yield, installation of submersible motor pump over sump well & electric connection from cseb, construction of brick masonry switch room of size 1.2*1.2*2.4 mtr ,construction of boundary wall around the overhead tank. Installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(f.h.t.c) in individual households and government instiution etc. complete with trial run operation & maintenance for 06 months under retrofittings of piped water supply scheme under jal jeevan mission for village tarri, kanhera & mundara block abhanpur district – .
|