Tender Detail with Corrigendum

Corrigendum - 10 Published On : 05/05/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 9 Published On : 04/05/2024
Corrigendum Details :Deadline has been changes from May 6 2024 12:00AM to May 17 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 8 Published On : 01/05/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 7 Published On : 22/04/2024
Corrigendum Details :Deadline has been changes from Apr 22 2024 12:00AM to May 6 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 6 Published On : 22/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 5 Published On : 13/04/2024
Corrigendum Details :Deadline has been changes from Apr 15 2024 12:00AM to Apr 22 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 4 Published On : 13/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 3 Published On : 02/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 2 Published On : 29/03/2024
Corrigendum Details :Deadline has been changes from Mar 29 2024 12:00AM to Apr 15 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 1 Published On : 22/03/2024
Corrigendum Details :Deadline has been changes from Mar 20 2024 12:00AM to Mar 29 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Buyer/Seller : Can be viewed by Subscribers
Ref. Number : 70081521
Pre-Qualification :

Years of Past Experience Required for same similar service : 3 Year (s)
MSE Exemption for Years Of Experience and Turnover : Yes
Startup Exemption for Years Of Experience and Turnover : Yes
Document required from seller : Experience Criteria,Certificate (Requested in ATC),OEM Authorization Certificate,Additional Doc 1 (Requested in ATC),Additional Doc 2 (Requested in ATC),Additional Doc 3 (Requested in ATC),Additional Doc 4 (Requested in ATC),Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Requirement : Supply of Group Tender for Various Medical Equipment (g 6- Physiology, Anatomy Community Medicine) (q3) Von Freyaesthesiometer, 1 Should Microprocessor Controlled, 2 Should Have Computer Connectivity for Data Logging., 3 Should Work on the Temperature Range of 5 Deg C to 55 Deg C, 4 Should Have Sampling Rate of 18 Samples/sec Or More, 5 Should Have a Starting Temperature 25° C to 40° C, 6 Temperature Increment Rate 0.2 Deg/s to 2.5 Deg/s, 7 Temperature Decrement Rate 0.2 Deg/s to 2.5 Deg/s, 8 Delay Between the Repeats Should Be 3 to 30 Secs, 9 Power Supply – 220v 50hz, 10 Manufacturer Should Be Iso 13485 Certified, Item No. 02, Anthropometric Set – Digital, 1 Digital Weight Scale with Weights for Scale Calibration, Set of Fifteen 10kg Calibration Weights., 2 Electronic Stadiometer with Calibration Rods., 3 Electronic Infantometer., 4 Skinfold Caliper., 5 Step Wedge Standards., 6 Measurement Box for Upper Leg Length and Calf Circumference., 7 Portable Weight Scales (2 Nos), 8 Steel Measuring Tape, 9 Insertion Tape, 10 Computer Terminal, 11, Computer Specifications 19” Monitor, 4gb Ram, 500gb Hd, Latest Windows Operating System with, Printer., 12 Standards, Safety and Training, a Should Have Iso Certification., 13 Documentation, a, Two Numbers of Complete User/technical Maintenance Manuals to Be Supplied in English (soft Copy, and Hard Copy)., Accessories, I Cosmetic Pencils (wax Base), Ii Baby Oil, Item No. 03, Electronic Muscle Stimulator, 1 Should Do Elicitation of Muscle Contraction Using Electric Impulses, 2 Should Be Solid State Microprocessor Controlled Unit with Digital Timer and Intensity Display, 3 Microprocessor Controlled Pulse Duration 0.3, 1, 10, 30, 100, 300ms, 4 Pulse Repetitive Frequency 0.3, 1, 3 Seconds, 5 Intensity Variation 0 to 130volts, 6 Output Voltage 100 Acv to 260 Acv, 7 Protection Class - I Complies with Iec 601-1, 8 Accessories - Electrode Set, 9 Power Supply – 220 to 240 Vac, 50hz, 10 the Stimulator Should Be Compatible with 3 Channel Digital Physiograph., Item No. 04, Priestly Smith Perimeter, 1 Should Have a Calibrated Arc, Revolving Chart Holder., 2, Should Be Able to Rotate in Any Direction and Fix at Any Position with a Tightening Screw. the Arc, Should Be Graduated From 0° to 90° with a Movable Test Object., 3, at the Back of the Arc Arrangement Should Be Provided for Fixing of Chart Which Has Concentric Circles, Corresponding to the Degrees of Arc., 4 Adjustable Chin Rest with Leveling Rod., 5 the Above Mentioned Should Be Fitted Over a Sturdy Base with Receptacle for Keeping Charts., 6 Accessories, A), Different Sized (2mm, 5mm, 10mm), Shaped (round & Square) and Colored (white, Blue, Green, Red, , Yellow) Objects., B) Should Be Supplied with 20 Packets of Charts (100 Charts/packet)., Item No. 05, Apparatus for Passive Movement, 1 Cpm is Used to Treat Joints of the Lower Limb After An Injury, Disease Or Following Surgery., 2, Based on a Concept Originated By Salter in 1970, This Device Has Varied Applications Namely, Treatment of Intra Articular Fractures, Septic Arthritis, Ligaments Tendon Healing and Also Following Total, Joint Replacement to Ensure a Sufficient Range of Motion., 3 to Prevent Stiffening , the Jouint Have to Be Moved Continuously Which Results in the Following., 4 Minimize Swelling and Pain After Operation, 5 Ensures Faster Recovery and Shortened Hospital Stay, 6 Prevents Extra Articular Contractures and Adhesions., 7 Ext/flex Angle Indicator at Knee Position, 8 Compact and Elegant Construction, 9 Electronic Controls Enable All Adjustment of Angle to Be Made on the Front Panel., 10 Smooth and Silent Movement, 11 Digital Timer with Alarm, 12 Patient Safety Switch for Stopping and Reversing the Motion., 13 Specifications, 14 Treatment Time 0 – 99 Minutes, 15 Reset Time 1 to 5 Seconds, 16 Angle Extension 0, 17 Power 230v/ac/50hz, 75va, Item No. 06, Physiograph Single Channel, 1, Student Physiograph Should Be Single Channel Console with 9 Speed (0.5, 1, 2, 5, 10, 20, 25, 30 & 50, Mm/sec) Tft/lcd Display, Time & Event Markers and Appropriate Transducers and Inbuilt Stimulator., 2 Couplers Strains Gauge and Isotonic, 3, Transducers Volume, (eeg/eog/emg Disc Electrodes, Gsr Transducers, Ecg Electrodes, , Respiration Belts, Temperature Electrodes for Human Physiology), 4 Accessories, Spares and Consumables, I Earth Lead, Ii Fuse, Iii Cover, Iv Power Supply Power Input to Be 220-240 Vac , 50 Hz, 5 It Should Be Stand Alone System., Item No. 07, Transilluminator with Uv Stand and Uv Torch, 1 for Visualization of Ethidium Bromide Stained Nucleic Acids., 2 High Output Uv Tube with Average Life Expectancy of 5000 Hrs., 3 Uv Light Facility with Wavelength Range 254-365 Nm., 4 Uv Protective Shield Which Can Block 99.5% of Uv Radiation, 5 Should Be Able to Detect Dna Less Than 10 Nanogarm., 6 Filter Size Approximately 20 X 20 Cm., 7 Can Be Used in Routine Electrical Point (220-230v)x 50hz., 8 with Spare Bulbs., 9 Uv Face Shield, 10 Uv Torch, 11 Manufacturer Should Be Iso 13485 Certified, Item No. 08, Fume Cupboard, 1, Fume Cupboards is a Fume Cabinets Which Localised the Fume Extraction Systems Fitted in Laboratories, to Protect Users From Harmful Substances That Could Be Inhaled. It Should Have a Cabinet with a, Moveable Front Window Made Out of Safety Glass. It Should Properly Functioning the Fume Hood, Exhausts Hazardous Gases, Dusts, Mists, Vapors From a Combined Location. Cabinet Structure, Material All Steel (1.0mm Cold-rolling Steel Or 1.0mm Stainless Steel) Covered with Electrostatic, Spraying After Folding, Welding, Polishing, Acid Cleaning, Phosphorization and Chemical Resistance. It, Should Have All the Accessories That is Required, Item No. 09, Fat Extraction Apparatus, 1 Extraction Apparatus, Fat, Complete, 2 Fat Extractor Used to Determine Fat and Oil Content in Samples., 3 Measurement Based on Aoac Methods., 4 Frame is Constructed of Anodized Aluminium Or Better., 5 Power Consumption 700 Watt, , 6, Spring-loaded Heater Elements Operated By Control Knobs / Key Pads with Variable Heat Input From 20-, 100% Capacity;, 7 Red Pilot Light, 8 Metal Condensers with Type 304 Stainless Steel Heads with Automatic Pressure-release Valves, 9 On/off Switch;, 10 Control Valve for Connection to Cold Water Supply;, 11 Water Outlet for Connection to An Open Drain, 12 Accessories, I 12 Borosilicate Glass 100 Ml Beakers., Ii 6 Alundum Extraction Thimbles, , Iii 6 Heat Covers, , Iv 6 Cork Gaskets, , V 6 Beaker Rings., Vi 6 Upper Condenser Gaskets, , Vii 9 Sample Tubes, , Viii 6 Support Stirrups and, Ix 9 Borosilicate Glass Reclaiming Tubes., X Manufacturer Should Be Iso 13485 Certified., Item No. 10, Ophthalmoscope, 1 Should Be Battery Operated., 2 Should Have Red-free and Cobalt Blue Filters., 3 Should Have Led Illumination, 4 Should Have Small and Large Spot Sizes, Fixation Targets, Slit Aperture, hemi-spot and Cobalt Blue Filter., 5 Should Have Wheel Control with Lens Powers Ranging From +20d to -35d, 6 Should Have Illuminated Lens Dial., 7 Should Have Rubber Brow Rest., 8 Should Have Dust Free Optics and a Spherical Optical System., 9 Should Be Supplied with a Carrying Case., 10, Should Have the Iso Certification and the Copy of the Same Should Be Enclosed Along with the, Technical Bid., Item No. 11, Sound Level Meter, 1, Multi-function Environment Meter Which Has the Functions of Sound Level Meter, Light Meter, Humidity, Meter and Thermometer., 2 Sound Level Meter Measuring Range - 35 to 130db, +/-3.5db at 94db., 3 Light Meter Measuring Range - 20 to 20, 000 Lux, +/-5% Reading., 4 Humidity Meter - 25% to 95% Rh - +/-5%rh (at 25°c, 35% to 95% Rh)., 5, Thermometer - 20 to 750°c, +/-3% Reading +/-2°c (-20 to 200°c), +/-3.5% Reading +/-2°c (200 to, 750°c)., 6 Resolution 0.01lux, 0.1°c&°f, 0.1%rh, 0.1db., 7 Measuring Rate 1.5 Times Per Second., 8 Should Have An Lcd Display for Parameter Display., 9 Should Work on Battery Power Source with Charger., 10 It Should Have Data Storage Capacity of at Least 500

Key Values

Closing Date : 17/05/2024
Location : Andhra Pradesh - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.