Tender Detail with Corrigendum

Corrigendum - 2 Published On : 09/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Corrigendum - 1 Published On : 08/04/2024
Corrigendum Details :Deadline has been changes from Mar 21 2024 12:00AM to Apr 17 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Buyer/Seller : Can be viewed by Subscribers
Ref. Number : 69915669 Tender Number : GEM/2024/B/4664012 Tender Prod. No : GEM/2024/B/4664012
Pre-Qualification : Minimum Average Annual Turnover of the bidder (For 3 Years) (3 ) : 80 Lakh (s)
OEM Average Turnover (Last 3 Years) ( 3 ) : 140 Lakh (s)
Years of Past Experience Required for same similar service : 3 Year (s)
MSE Exemption for Years Of Experience and Turnover : Yes
Requirement : Providing and Fixing of Ceiling Panel System, Providing and Fixing of Wall Panel System, Providing and Fixing of Corner Coving, Providing and Fixing of Pvc Flooring with Self Levelling Antistatic Conductive Roll, Sitc of Laminar Air Flow System, Sitc of Peripheral Lighting and Clean Room Luminaries, Sitc of Ot Panel is Fixed Flush in the Theater, Sitc of Xray Film Vilwer, Providing and Fixing of Pressure Relief Dampers, Sitc of Air Tight Swing Type Double Leaf Door, Providing and Fixing of Operating List Board, Sitc of Scrub Station, Sitc of Surgical Ot Led Light, Sitc of Single Movable Pendant for Anasthesist, Sitc of Medical Gas Pipeline, Storage Cabinet, Supply Fixing of 6a Switch 6a Socket with 6 Modular Gi Box Surface Plate, Supply Fixing of 16a Switch 16a Socket with 16 Modular Gi Box Surface Plate, Rj 45 Cat 6 Utp 1 Module for Data, Rj 45 Cat 6 Utp 1 Module for Telephone, Etpn Db 8way Ip43 Ik 09 with Metal Door, Mcb 32a 1 Pole C Curve, Mcb 10a 1 Pole C Curve, Mcb 20a 1 Pole C Curve, Rccb 63a 4 Pole 100 Ma, Isolator 63a 4 Pole, 150x50x18 Swg Gi Cable Tray Perforated Type, 2 X 2 Half Sq Mm Plus 1x 2 Half Sq Mm Earth Cu Wire, 4 X 4 Sq Mm Plus 2 X 4 Sq Mm Earth Wire Cu Wire, 25 X 4 Core Xlpe Armored Aluminum Flexible Insulated Cable, 4 Pair Cat 6 Lan Cable in Existing Pvc Conduit Required 1 Run, Supplying Fixing 25 Mm Size of Still Conduit Along with Accessories, Sitc of on Line Central Ups 10 Plus 5 Kva 1w Plus 1s, Hvac Work Sitc of Dx Based Ahu of 3500 Cfm, Copper Pipe 15 Decimal 86 Mm Dia Od Soft Drawn with Tube Thickness 1 Decimal 2 Mm with 19 Mm Thick Insulation Or as Recommended By Oem, Copper Pipe 28 Decimal 58mm Dia Od Hard Drawn with Tube Thickness 1 Decimal 2mm with 19mm Thick Insulation Recommended By Oem, Sitc of Vrf Outdoor Unit of 16 Hp with Ahu Kit, Sitc Vfd Drive for Ahu, Sitc of Uvgi Lamp for 3500 Cfm, Sitc of Duct Heater 4 Kw, Hvac Ducting Exhaustion System Al Ducting, Insulation, Volume Control Damper, Fire Control Damper, Ra Grill, Sitc of Exhaust Fan, Actuator, Wooden Partition

Key Values

Closing Date : 17/04/2024
Location : West Bengal - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.