Tender Detail with Corrigendum

Corrigendum - 5 Published On : 16/04/2024
Corrigendum Details :Deadline has been changes from Apr 15 2024 12:00AM to Apr 30 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Corrigendum - 4 Published On : 16/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Corrigendum - 3 Published On : 02/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Corrigendum - 2 Published On : 29/03/2024
Corrigendum Details :Deadline has been changes from Mar 29 2024 12:00AM to Apr 15 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Corrigendum - 1 Published On : 22/03/2024
Corrigendum Details :Deadline has been changes from Mar 20 2024 12:00AM to Mar 29 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Available Corrigendum Document For Download
Buyer/Seller : Department Of Health And Family Welfare
Ref. Number : 70042369 Tender Number : GEM/2024/B/4736384 Tender Prod. No : GEM/2024/B/4736384
Pre-Qualification :

Years of Past Experience Required for same similar service : 3 Year (s)
MSE Exemption for Years Of Experience and Turnover : Yes
Startup Exemption for Years Of Experience and Turnover : Yes
Document required from seller : Experience Criteria,Certificate (Requested in ATC),OEM Authorization Certificate,Additional Doc 1 (Requested in ATC),Additional Doc 2 (Requested in ATC),Additional Doc 3 (Requested in ATC),Additional Doc 4 (Requested in ATC),Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Requirement : Supply of Group Tender for Various Medical Equipment (g 8-bio Chemistry) (q3) the Glassware Should Be Made of High Quality Borosilicate Glass to Withstand High Heat., 2 Apparatus Capacity Should Be of 4 Litres/hr., 3 Should Be Double Stage., 4 Should Have Metallic Stand and Other Accessories., 5 Stand Should Be Made of Rust Free Material., 6 Standards Heating Elements of 2.5-3kw to Be Used., 7 An Automatic Cut Off Device Should Be Attached., 8 Heather Should Be of Quartz for Immediate Output of Distilled Water. Apparatus Should Consist of High, Quality Borosilicate Boiler with Built in Water Leveller., 9 Output Water Should Be Pyrogen-free with Conductivity Less Than 1 Micro Siemen, Ph 6.9-7, Distillate, Temp 65-75 Deg C., 10 Metal Stand., 11 Automatic Cut Off Device Or Safety Control Module., 12 Power Input to Be 220-240 Vac, 50 Hz., 13 Manufacturer Should Be Iso 13485 Certified, Item No. 2, Analytical Balance, I Description of Function, 1 Electronic Balance is Required for Precision Weighing of Lab Samples, Ii Technical Specifications, 1 Weigh Accurately Up to 3rd Decimal Place, 2, Fully Automatic Time and Temperature Controlled Internal Calibration and Balance Should Be, Capable to Adjust Itself, 3 Auto Zero Setting, 4 Weighing Capacity Up to 200g, 5 Readability 0.001g, 6 Repeatability 1mg Or Less, 7 Setting Time - Less Than 2 Seconds, 8 Suitable for Internal/external Adjustment Weights, 9 Pc Connectivity, Iii Balance Should Have, 1 Liquid Crystal Display (lcd) for Display, 2 Ir Sensors for Hands Free Operation, 3 Warns If Balance is Not Correctly Levelled, 4 Automatic/manual and Detachable Draft Shield, 5 Detachable and Adjustable Terminal, 6 Facility for User Administration and Password Protection, 7 Integrated Automatic Safety Function for External Routine Operations, 8 Alphanumeric Data Entry of More Than 2 Ids, 9 Should Be Bis/ Iso Certified and Certificate to Be Provided., Iv Power Supply, 1 Power Input to Be 220-240vac, 50hz, 2 Deleted, 3, Suitable Ups with Maintenance Free Batteries for Minimum One-hour Back-up Should Be, Supplied with the System, 4 Resettable Over Current Breaker Shall Be Fitted for Protection, Item No. 3, Vertical Autoclave, 1 the Vertical Autoclave Should Have Chamber Capacity Of Effective Volume 113 Litres Or More., 2, the Chamber of Vertical Autoclave Should Be Manufactured as Per Asme Standards and, Comply with Pressure Equipment Directive, 3, the Vertical Autoclave Should Work on the Domestic Power Supply of 230 V Ac, 50 Hz, Single, Phase, 4, the Vertical Autocalve's Internal Chamber, Cover Lid and All Wetted Parts Should Be Fabricated, From Stainless Steel of 304 Grade, 5 the Vertical Autoclave Outer Body Should Be of Ss 304., 6 Temperature Range Should Be Up to 135°c and Pressure Up to 30 Psi., 7 the Vertical Autoclave?s All Joints Should Be Smooth Finished for Crevice Free Internals., 8, the Chamber Should Be Hydro Statically Tested at 1.5 Times of Its Working Pressure and, Certificate Should Be Supplied for the Same, 9, the Lid Should Be Equipped with Single Lever Lock Mechanism and Lever Handle Moulded From, Industrial Plastic, 10 the Lid Should Be Provided with Auto Purge Cum Vacuum Breaker Valve and a Manually, Operable Valve for Exhaust., 11 the Unit Should Have a Solenoid Valve for Auto Purging of Air & Normal Exhaust, 12 the Vertical Autoclave Should Have Stainless Steel Pressure Gauge with Dual Range Dial Display, in Kpa and Psi Along with a Co-related Temperature Scale for Steam in Degrees Celsius, 13 the Operations of the Unit Should Be Controlled By Touch Screen Programmable Logic, Controller with 4 Temperature Channels & 1 Pressure Channel Inbuilt., 14 the Autoclave Should Be Equipped with Touch Screen Hmi Plc., 15 Controlling of Chamber Temperature Should Be on All 4 Temperature Channels, 16, to Ensure Proper Sterilization Cycle Autoclave Should Have Facility of Connecting External, Printer Which Can Give Instant Print of All Cycle Data – Customer and Operator Name , Equipment, Number, Recipe, Hold Time, Batch Number, Date & Time, Temperature Set-point, Readings of at, Least Four Temperature Sensors, Pressure Channels F0 Summation and Cycle Status., 17 Inbuilt 6 Recipes for Different Load Should Be Available., 18 Provision of Automatic Water Filling Should Be Available., 19 the Timer Should Be Retentive & Settable Up to 95 Mins, 20, Power Fail Restoration Facility in Case of Power Failure, the Autoclave Should Give Option of, Resuming Cycle with Automatic Adjustment of Sterilization Hold Time, 21 the Unit Should Have Safety Valve to Protect the Equipment in Case of Over Pressurization, 22 the Lid Should Be Equipped with Pressure Interlock Device to Avoid Opening Under Pressure., 23 Lid Should Be Equipped with Door Switch to Avoid Cycle Start If Door is Not Locked Properly., 24 to Ensure Effective Sterilization, If Temperature Falls Below Temperature Set Point the, Sterilization Timer Should Get Automatically Adjusted., 25 the Unit Should Be Provided with Independent Safety Cut-out for High Temperature, 26, the Unit Should Give Indication By Audio-visual Alarm on Completion of Set Autoclave Cycle., 27 the Electrical Safety Should Be Ensured By Inbuilt Mcb, 28 the Unit Should Be Mounted on 04 Nos. Pu Coated Castors Out of Which Atleast 2 Should Have, Locking Mechanism, 29 the Vertical Autoclave Should Be Ped Certified and the Same Should Be Provided., 30 Manufacturer Shall Be Iso 13485 Certified, 31 Local Service Setup Should Be Available for Prompt and Efficient Post-sales Support., 32 Autoclave Should Have Service & Calibration Reminder Facility., 1) Autoclave Should Have the Provision of Password Protection so That Unauthorized People, Cannot Access the Equipment Or Cannot Change the Critical Set Parameters, 33 Calibration Reports Should Be Provided with Nabl Traceability., 34 Autoclave Should Have Option for (to Be Quoted Separately), 1) Air Ballast, 2) Positive Pulsing, 3) Drain Cooling, 35 the Calibration, Iq, Oq and Pq of the Instrument Should Be Performed at the Time of, Installation and Certificates Should Be Provided., 36, Document Supporting Track Record and Satisfactory Performance From Institutes of National, Importance (minimum One) Should Be Provided., 37, Support for Induction and Follow Up Training of Technical Staff, On-site Standardization and, Troubleshooting of Procedures/ Tests Should Be Provided By the Company, Item No. 4, Micro Balance, 1 Should Have Readability of 1µg, 2 Should Have a Weighing Capacity of Minimum 0-20 Gm, 3 Linearity Should Be ± 10 ?g, 4 Repeatability Should Be Atleast 1 ?g, 5 Should Work on An Operating Temperature of 18-30 ° C, 6 Ss Pan Size ( Diameter) Upto 40 Mm×40 Mm, 7 Response Time Should Be Within 5-10 Seconds, 8 Should Have Internal Calibration Facility, 9 Lcd Screen for Displaying Measured Values, 10 Packing Size Upto 565 ×565×355, 11 Should Have Glass Shield Cabinet, 12 Power Supply 230 V Ac +/- 10% 50 Hz, 13 Manufacturer Should Be Iso 13485 Certified,
Qty 11

Key Values

Closing Date : 30/04/2024
Location : Gautam Budh Nagar - Uttar Pradesh - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Tender Documents

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.