Tender Detail with Corrigendum

Corrigendum - 7 Published On : 22/04/2024
Corrigendum Details :Deadline has been changes from Apr 22 2024 12:00AM to May 6 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 6 Published On : 22/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 5 Published On : 13/04/2024
Corrigendum Details :Deadline has been changes from Apr 15 2024 12:00AM to Apr 22 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 4 Published On : 13/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 3 Published On : 02/04/2024
Corrigendum Details :Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 2 Published On : 29/03/2024
Corrigendum Details :Deadline has been changes from Mar 29 2024 12:00AM to Apr 15 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Corrigendum - 1 Published On : 22/03/2024
Corrigendum Details :Deadline has been changes from Mar 20 2024 12:00AM to Mar 29 2024 12:00AM
Date
Corrigendum Type :Date
Corrigendum Document : Can be viewed by Subscribers
Buyer/Seller : Can be viewed by Subscribers
Ref. Number : 70080961
Pre-Qualification : Years of Past Experience Required for same similar service : 3 Year (s)
MSE Exemption for Years Of Experience and Turnover : Yes
Startup Exemption for Years Of Experience and Turnover : Yes
Document required from seller : Experience Criteria,Certificate (Requested in ATC),OEM Authorization Certificate,Additional Doc 1 (Requested in ATC),Additional Doc 2 (Requested in ATC),Additional Doc 3 (Requested in ATC),Additional Doc 4 (Requested in ATC),Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Requirement : Supply of Group Tender for Various Medical Equipment (g 5- Pharmacology) (q3) Analgesiometer - Tail Flick (digital), 1 Description of Function, , This Tail Flick Unit is Required to Perform Rapid Precise Screening of Analgesic Drugs on the Rat and, Mice Tail., 2 Operational Requirements, Microprocessor Based System Required with Pc Connectivity, 3 Technical Specifications, , Should Consist of An I.r. Source, Whose Radiant Energy of Adjustable Intensity is Focused on the Rat, Tail., Restrainers Should Be Available to Be Used with Rat and Mice., the Instrument Should Automatically Detect the Withdrawal Latency to the Nearest 0.1 S., the Experimental Data Can Be Directly Exported to the Pc Usb Or Serial Ports., Dedicated Data Acquisition Software Package., 4 Standards, Safety and Training, Manufacturer Should Be Iso 13485 Certified, Calibration/acceptance Test Certificate From the Factory Required., Manufacturer/supplier Should Have Iso Certification for Quality Standards., , Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 5 Documentation, User/service Manual in English ( Both Soft and Hard Copy ) 2 Nos Must Be Provided, Sn Hot Plate Analgesia Meter, 1, Should Be Digitally Controlled and Consist of a Clear Acrylic Chamber/s and Aluminium Plate Providing, Good Temperature Stability and Even Surface Distribution, 2 Operating Temperature Upto 75 Degree Celsius, 3 Digital Display of Temperature Should Be in 0.1 Deg C Increments, 4 Foot Switch to Allow Control of Start and Stop and Permit Hands Free Operation, 5 Should Be Suitable for Both Rats as Well as Mice, 6 Digital Display of Reaction Time in 0.1 Sec Increments., 7 Data Can Be Transferred to Pc Using Usb/ Serial Port., Sn Polygraph (sixteen Channel Research), 1.1 No of Channels 16. It Should Be Able to Use Both for Animals and Humans., 1.2 Ethernet/high Speed Usb Data Acquisition and Analysis Software., 1.3 Apparatus for Recording and Calculating Hrv and Blood Pressure Variability, Temperature, 1.4, Transducers and Softwares for Recording and Analyzing Plethysmography, Gsr, Skin, Temperature, continuous Real-time Beat-to-beat Blood Pressure, Non Invasive Cardiac Out Put, , Respiration, Phonocardiogram and Pulse Tonometer for Carotid Pulse, Baroreflex Sensitivity and Total, Peripheral Resistance Recording., 1.5 21 Inch Tft Monitor, 1.6 1tb Storage Facility, 8gb Ram, I7 Processor, Or Better Configuration Computer, 1.7 Colour Laser Printer, 1.8, Wireless (transmitter / Recorder) Device with Transmit Range Up to 100m, Memory Capacity 480 Hours, , 250 Hz Sampling Rate, Radio Band Frequency, 2 Accessories, Spares and Consumables, 2.1 Necessary Cables and Batteries, 2.2 Computer with Laser Printer to Be Attached to the Equipment, as in Point 1.6 and Point 1.7, 3 Standards, Safety and Training, 3.1 Manufacturer Should Be Iso 13485 Certified, 3.2 Calibration/acceptance Test Certificate From the Factory Required., 3.3 Manufacturer/supplier Should Have Iso Certification for Quality Standards., 3.4, Should Have Local Service Facility .the Service Provider Should Have the Necessary Equipments, Recommended By the Manufacturer to Carry Out Preventive Maintenance Test as Per Guidelines, Provided in the Service/maintenance Manual., 4 Documentation, 4.1 User/service Manual in English, 4.2, Compliance Report to Be Submitted in a Tabulated and Point Wise Manner Clearly Mentioning the, Page/ Para Number of Original Catalogue/data Sheet. Any Point, If Not Substantiated with Authenticated, Catalogue/manual, Will Not Be Considered., 5, Multi Channel Universal Bio-amplifier for Ecg, Emg, Eeg, Eog (at Least 8 Channels) Along with, Cardio Axis Analysis., Sn Electro Convulsiometer, 1 Description of Function, 1.1, to the Study of Anti-convulsion and Anti-epileptic Drugs, Whether for Education, Screening Or, Manufacturing of Drugs, 2 Technical Specifications, 2.1, Should Provide 50hz Stimulus Current Variable From 0.25ma to 330 Ma Through Touch Panel Controls, for Producing Minimal and Supra-maximal Seizure in Small Animals, 2.2 the Duration of Stimulus Current is Variable From 0.1 Second to 9.9 Second in Steps of 0.1 Second, Sn Electro Convulsiometer, Led Indicator for Duration of Stimulus., 2.3 Power Supply 230v 50hz, 2.4 Should Be Supplied with Corneal Electrode Pair (different Cup Size) and Ear Clip 2 Pairs, Should Have Digital Display of Parameters Like Time and Current., 3 Standards, Safety and Training, 3.1 Manufacturer Should Have Iso Certification, 4 Documentation, 4.1 User/technical Manual Should Be Supplied, 5 Experiment Data Exported to Pc Or Dedicated Data Acquisition Software Package., Sn Cooks Pole Climbing Apparatus, 1 Description of Function, 1.1, for Studying Cognitive Function, Mainly Response to Conditioned Stimulus During Learning & Its, Retention, 2 Technical Specifications, 2.1 Digital Voltmeter 16 - 200 V Dc., 2.2 Digital Timer 0.1 - 999 Sec., 2.3 Digital Delay Timer 0.1 - 999 Sec (cyclic)., 2.4 Complete Chamber and Tray Made of Thick Imported Acrylic Sheets., 2.5 Climbing Pole of Bakelite., 2.6, the Experimental Chamber Has a Grid Floor Sliding Door with a Clear Perplex Front. Electric Buzzer and, Chamber Light. Stimulator with Built in Timer to Provide Shock of 440 V 0.2 Ma at a Frequency of 5 Per, Second. the Duration Also Controlled Manually., 2.7 It Should Be a Compact Model, 3 Standards, Safety and Training, 3.1 Calibration/acceptance Test Certificate From the Factory Required., 3.2 Manufacturer/supplier Should Have Iso Certification for Quality Standards., 4 Documentation, 4.1 User/service Manual in English, 4.2, Compliance Report to Be Submitted in a Tabulated and Point Wise Manner Clearly Mentioning the, Page/para Number of Original Catalogue/data Sheet. Any Point, If Not Substantiated with Authenticated, Catalogue/manual, Will Not Be Considered., Sn Rota Rod Apparatus for Rat & Mouse, , 1. Single System for Mice and Rats with Separate Rotor for Each Species, Rat Rotor Diameter-60 Mm &, Mice Rotor 30 Mm Diameter, 2. for Testing Atleast 4 Animals at a Time, 3. Drum Must Be Electronically Controlled – Not Belt Driven, 4. Sensors Must Not Require Any Adjustment and Must Use Magnetic Sensing Switches, Sn Rota Rod Apparatus for Rat & Mouse, 5. Test Length Should Be Adjustable Between 1 to 999 Secs, 6. It Should Be Possible to Conduct the Test in Both Forward and Reverse Modes, , 7. Start, Stop and Reset Buttons Should Be Available. a Digital Display Must Allow the User to View All, Parameters and Test Results for All Individual Animals, 8. the Distance Covered, Rod Speed When the Animal Fell and Length of Test Must Be Recorded, 9. Start Speed Should Be Variable From 0 – 40 Rpm, 10. Front Panels Should Prevent Escape of Animals, 11. Instrument Must Have Printer Interface and Software for Data Recording Must Be Available, Digital Photoactometer, 1 Technical Specifications, 1.1, Solid State Instrument for Monitoring Spontaneous & Induced Ambulatory (horizontal and Vertical), Activity of Laboratory Animals., 1.2 12(6 Pairs) Photoelectric Activity Sensors Which Form Mesh of Beams in Shape of Square., 1.3 30cmx30cmx30cm Animal Cage with Top Cover and Sliding Tray at the Buttom, 2 Standards, Safety and Training, 2.1 Manufacturer Should Have Iso Certification, 3 Documentation, 3.1 User/technical/service Manual Should Be Provided, 4 Software Must Indicate Fast and Slow Movements, Fast and Slow Stereotypy and Reaming., Portable Autoclave, 1 Suitable of General Laboratory Use as Well as for Field Sterilization of Instruments and Dressings Etc., 2 It Should Be Portable with Capacity 20-25 L, 3 the Sterilizer Should Be Made Up of S.s. Sheet Deep Drawn to Cylindrical Shape., 4 Dome Shaped S.s. Lid is to Be Provided Which Will Seal the Autoclave with Neoprene Joint Less Gasket., 5 the Lid Should Be Tightened to the Body When Closed

Key Values

Closing Date : 6/05/2024
Location : Uttar Pradesh - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.