Tender Detail

Buyer/Seller : Can be viewed by Subscribers
Ref. Number : 70546661 Tender Number : GEM/2024/B/4791918 Tender Prod. No : GEM/2024/B/4791918
Pre-Qualification :

Minimum Average Annual Turnover of the bidder (For 3 Years) (3 ) : 13 Lakh (s)
OEM Average Turnover (Last 3 Years) ( 3 ) : 3 Lakh (s)
Years of Past Experience Required for same similar service : 3 Year (s)
MSE Exemption for Years of Experience and Turnover : No
Startup Exemption for Years of Experience and Turnover : No
Document required from seller : Experience Criteria,Past Performance,Bidder Turnover,Certificate (Requested in ATC),OEM Authorization Certificate,OEM Annual Turnover,Additional Doc 1 (Requested in ATC),Additional Doc 2 (Requested in ATC),Additional Doc 3 (Requested in ATC),Additional Doc 4 (Requested in ATC),Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Past Performance : 80 %

Requirement : Supply of Mechanical Lab Instruments (q3) Thermal Conductivity of Metal Rod Apparatus, Specifications, • Metal Bar Copper - 25 X 430 Mm Long, (approx), • Insulating Powder Shell – 200mm Dia, (approx), • Cooling Water Chamber – 100mm Dia X 75, Mm Long (approx), • Control Panel Comprising of –, A) Voltmeter 0 – 200 Volts., B) Ammeter 0 – 2amp, C) Digital Temperature Indicator, 0-300° C, 1, 2 Heat Transfer From a Pin Finapparatus, Specifications, • Fin – 12.5 Mm (approx) 15 Cm. Long, (approx). One Each of Mild Steel, Aluminum, and Brass. Duct Size – 10 Cm X 15 Cm X 80, Cm Long Blower of Suitable Capacity with 0.5, H.p. Single Phase Motor. Heater –, Nichrome Wire Type Bank Heater of Suitable, Capacity, • Control Panel Comprising of , A) Voltmeter – 0 – 200 Volts., B) Ammeter – 0 – 2 Amp, C) Dimmer Stat for Heater 0-230 Volts 2 Amp., D) Temperature Indicator – 0 – 300°c with, 10°c Least Count . Using Chrome, Alumel Thermocouples, Provided with Cold, Junction Compensation. Orifice Meter on, Blower Outlet with Water Manometer. Fins of, Other Materials Can Be Supplied at Extra, Cost., 1, 3 Emissivity Measurement Apparatus, Specifications, • Test Plate & Reference Plate Size – 160mm Dia., • Enclosure with One Side of Perspex Sheet., • H E a T E R- 2 0 0 V, 4 0 0 W a T T , n I C H R O M E W, I R E T Y P E .sandwiched Between Mica Sheets., • Control Panel Consisting of –, • Voltmeter – 0 – 200 V , , • Ammeter – 0 – 2 Amp, • D. P. D. T. Selector Switches for, Voltmeter & Ammeter., 1, Institute of Engineering and Technology, Mohanlal Sukhadia University, Udaipur (raj.) 313001, _____________________________________________________________________________________, • Digital Temperature Indicator 0-300°c., Usingchromel–alumelthermocouples Provided., • Dimmer Stats for Test Plate and Black Plate., Special Notes, Manufacturer Must Have R & D Centre Duly Recognized, By Department of Scientific and Industrial Research, , Ministry of Science and Technology., Oem/suppliers Should Have Iso & Ce Certified, Manufacturer Who Can Ensure the Manufacturing of, the Machine as Per the Required Testing, Standards/bs/bls/astm Standards and Within the, Specified Tolerance Limits. Oem Authorization Should, Be Compulsorily Attached with the Technical Bid., Oem Must Have the Authorized Service Center in, the State of Rajasthan, Oem/bidder Must, Attached Dsir Certificate with Technical Bid., 4 Stefan Boltzman Apparatus, Specifications, • Hemisphere Dia – 200 Mm (approx)., • Jacket Disc - 250 Mm., • Test Disc Size – 20 Mm Dia X 1.5mm Thickness., • Water Tank of Sufficient Capacity with a 1.5 Kw, Immersion Heater. Control Panel Comprises of -, I) Supply for Heater., Ii) Digital Temperature Indicator 0-200°c Using, Chormal- Alumel Thermocouples, , Provided with Cold Junction Compensation., Iii) Built in Timer for Temperature Readings at 5, Seconds Interval., 1, 5 Heat Transfer in Natural Convection Apparatus, Specifications, • Enclosure Size 20 Cm X 20 Cm X 75 Cm., • Tube Size (test Cylinder) 38mm (o. D.) X 50, Cm Long, • Nichrome Heater (cartridge Type), • Control Panel Comprising Of, I) Voltmeter – 0 – 200 V, Ii) Ammeter – 0 – 2 Amp, Iii) Dimmerstat - 0 - 2amp, 240v, Iv) Digital Temperature Indicator 0-200°c Using, Chormal- Alumel Thermocouples, , Provided with Cold Junction Compensation, 1, 6 Critical Heat Flux Apparatus, Specifications, • Voltmeter 0 - 200 Volts, • Ammeter 0 - 5 Amp, • Cylindrical Glass Vessel Diameter 200mm, Approx., • Cylindrical Glass Vessel Height 125mm, Approx., • Bulk Heater - Nichrome Coil., • Test Heater - Nichrome Wire., 1, Institute of Engineering and Technology, Mohanlal Sukhadia University, Udaipur (raj.) 313001, _____________________________________________________________________________________, • Thermometer - 10° to 100°c., 7 Parallel Flow and Counter Flow Heat Exchanger, Specifications, • Length of Heat Exchange 1.6 M Outer Late, Material G. I., • I. D. – 27.5mm O. D. – 33.8mm, • Inner Tube Material – Copper O.d, 12.7mm, • Thermometer 0° to 200°c–1nos., • Geyser – Instantaneous Type. 3kw Capacity – 1 No., • Measuring Flask – 1000 with Stop Clock., 1, 8 Heat Transfer in Forced Convection, Specifications, • Dia & Length of Test Section – 28 (approx.) X, 40 Cms., • No. of Thermocouples – 6 Nos., • Nichrome Heater of Suitable Capacity, • Blower 0.5 H.p. with Motor with 12” of, Wgp., • Orifice & U Tube Manometer., • Control Panel Comprising of, I. Dimmer Stat 240 V, 2 Amp, . A.c., Ii. Voltmeter 0 - 200 V., A.c., Iii. Ammeter 0 - 200 V., A.c, , Special Notes, Manufacturer Must Have R & D Center Duly Recognized, By Department of Scientific and Industrial Research, , Ministry of Science and Technology., Oem/suppliers Should Have Iso & Ce Certified, Manufacturer Who Can Ensure the Manufacturing of, the Machine as Per the Required Testing, Standards/bs/bls/astm Standards and Within the, Specified Tolerance Limits. Oem Authorization Should, Be Compulsorily Attached with the Technical Bid., Oem Must Have the Authorized Service Center in, the State of Rajasthan, , 1, 9 Dial Gauge, Dial Gauge Lever Type Dial Test Indicator L.c., 0.01mm. Range 0.8mm., 1, 10 Micrometer, 0.150 Mm ----0-150mm, 1, 11 Vernier Caliper, 0.150 Mm ----0-150mm, 1, 12 Telescopic Gauges, Set of 6 Pcs, 1, 13 Vernier Bevel Protector 1, 14 Slip Gauges Box 1, Institute of Engineering and Technology, Mohanlal Sukhadia University, Udaipur (raj.) 313001, _____________________________________________________________________________________, Set 38 Pcs (grade Ii) with Individual Calibration, Certificate, Material Stainless Steel, 15 Sine Bar., Hardened and Ground Sine Bar with Accuracy, 100mm, 1, 16 Gear Tooth Vernier Caliper, Lc 0.02mm. Range 1 to 26 Modules, 1, 17 Profile Projector, Cooling System Built in Noiseless and Vibration Free, Blower for Powerful Cooling System., Magnification 10x, Surface Illumination 12v - 50w Halogen Lamp, with Reflector., Power Supply 220 / 240v Ac., 50 / 60hz, fuse 5a., Contour Illumination 24v - 100w Halogen Lamp., Telecentric System and Sharp Twin Lens Condenser for, Each Magnification, Magnification Accuracy +- 0.1% for Contour and +-, 0.15% for Surface., Screen Diameter 200mm. Fine Ground Screen, with Cross Line. Rotatable 0 to 360deg Vernier Reading, 2 Minutes., Work Stagetable 150x150mm. X & Y Axis, traverse, 25mm in Each Direction Having Least Count .01mm, 1, 18 Three Wire Unit (loose), Supplied with Bracket and You Have to Fit in Outside, Micrometer to Check the Threads. (set of Three, Pieces), 1, 19 Lathe Tool Dynamometer,
Qty 1

Key Values

EMD : INR 13,000
Closing Date : 6/04/2024
Location : Rajasthan - India

Value Added Services

  • Get consortium partner
  • Get Winning Estimate
  • Track Tender Result
  • Get Subcontractors
  • Find Liaison Agency
  • Ask Expert

Disclaimer : Tender Tiger takes all possible care to ensure accurate & authentic tender information however it cannot be held responsible for Omissions, Errors, etc. Users are advised to refer to Tender Document published by Procuring entity before they take submit their actual bid.