School of Chemical Science Renovation of Seminar Hall - Electrical Works <br /> "supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, , Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of, Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp, Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the, Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).single Control Light Point with 6a, Plate Ceiling Rose - Short Point", "supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, , Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of, Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp, Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the, Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).single Control Ceiling Fan Point with 6 a, 3 Plate Ceiling Rose & with Socket Size Stepped Electronic Regulator. - Short Point", Supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, Fixing the Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably and with 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650v Grade, Including Providing Switch Board Main and Continuous Earthing with No.14 Swg Bare Copper, required Quantity of Copper Earth Socket, Brass Bolt and Nut Crimping/ Soldering Etc Complete with Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (white) Etc. Up to and Including 6a Modular Type Sp Switches and Making Good the Surface of Wall, Colour Washing Etc. Complete. All the Terminations in the Switch Boards and Db's Shall Be Tinned and the Wires Shall Be Drawn and Fixed Along the Periphery of the Box Using Suitable Ties, Tie Mounts Etc as Required. (rohs Compliant Modular Accessories).combined Plug Point with 6 a, 5 Pin Plug Socket Controlled By 6 a, Switch in the Same Switch Board as That of Light Points, "supply and Fixing of Following Sizes of Light Gauge Pvc Conduit Along with Accessories in Surface/ Recess, Including Cutting the Wall and Making Good the Same in Case of Recessed Conduit as Required20 Mm", Supply and Fixing of Following Sizes of Light Gauge Pvc Conduit Along with Accessories in Surface/ Recess Including Cutting the Wall and Making Good the Same in Case of Recessed Conduit as Required25 Mm, Supply and Drawing 650/1100 V Grade Frls Pvc Insulated Stranded Single Core Copper Conductor Cables Conforming to is 694 Part I 1990 in the Existing Surface / Recess Conduit as Required Including Giving Necessary Connections of the Following Sizes.1.00 Sq.mm 2 Run, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 1.5 Sq.mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 2.5 Sq. Mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.3 X 4 Sq. Mm, Supplying and Drawing Following Sizes of Frls Pvc Insulated Copper Conductor, Single Core Cable in the Existing Surface / Recessed Steel/ Pvc Conduit as Required.5 X 4 Sq. Mm, Supply & Fixing the Following Types/ Sizes of Boxes Suitable for Modular Accessories in Surface/ Recess Including Making Good the Damages, Colour Washing Etc as Required (rohs Compliant )2 Module Moulded Plastic Box on Surface, Supply & Fixing the Following Types/ Sizes of Boxes Suitable for Modular Accessories in Surface/ Recess Including Making Good the Damages, Colour Washing Etc as Required (rohs Compliant )3 Module Moulded Plastic Box on Surface, Supply & Fixing the Following Types/ Sizes of Boxes Suitable for Modular Accessories in Surface/ Recess Including Making Good the Damages, Colour Washing Etc as Required (rohs Compliant )6 Module Moulded Plastic Box on Surface, Supply & Fixing the Following Types/ Sizes of Boxes Suitable for Modular Accessories in Surface/ Recess Including Making Good the Damages, Colour Washing Etc as Required (rohs Compliant )8 Module Moulded Plastic Box on Surface, Supplying and Fixing Following Modular Base & Cover Plate on Existing Modular Metal Boxes Etc. as Required.1 Or 2 Module, Supplying and Fixing Following Modular Base & Cover Plate on Existing Modular Metal Boxes Etc. as Required.3 Module, Supplying and Fixing Following Modular Base & Cover Plate on Existing Modular Metal Boxes Etc. as Required.6 Module, Supplying and Fixing Following Modular Base & Cover Plate on Existing Modular Metal Boxes Etc. as Required.8 Module, Supplying and Fixing Following Modular Switch/ Socket on the Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. as Required.5/6 Amps Switch, Supplying and Fixing Following Modular Switch/ Socket on the Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. as Required. 15/16 Amp Switch, Supplying and Fixing Following Modular Switch/ Socket on the Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. as Required.3 Pin 5/6 Amp Socket Outlet, Supplying and Fixing Following Modular Switch/ Socket on the Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. as Required.6 Pin 15/16 Amp Socket Outlet, Supply and Installation of Suitable Size Ms Rod Type Fan Clamp in the Rcc Slab as Per is 732 as Required., Supplying and Fixing Extra Down Rod of 10 Cm Length G.i. Pipe, 15 Mm Dia, Heavy Gauge Including Painting Etc. as Required. (note More Than 5 Cm Length Shall Be Rounded to the Nearest 10 Cm and 5 Cm Or Less Shall Be Ignored), "supply, Conveyance, Installation, Testing and Commissioning of Ceiling Fans of the Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring the Down Rod with 16/0.20mm Pvc Insulated and Pvc Sheathed 650/1100v Grade 3 Core Round Copper Conductor Flex Wire Or with Extended, Original Wiring Etc. as Required.1200mm Sweep -5star Rated Ceiling Fan Complete with 300mm Down Rod , Canopies, Shackles and Blades Working on 230v/240v Single Phase A/c", "supplying and Fixing of Following Ways Surface/ Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar,
School of Chemical Science Renovation of Seminar Hall - Electrical Works
"supply and Wiring Points According to is 732-1989 Using Rigid Pvc Conduit of Minimum Size 20 Mm with Specials Conforming to is 9537 Part Iii 1983 and with Suitable Size Specials Conforming to is 3419-1988, , Fixing the
Brick Tenders, Bus Bar Tenders, Cement Tenders, Circuit Breakers/Fuse Tenders, Civil Work Tenders, Conductor Tenders, Distribution Board Tenders, Diversified Electrical Spares And Stores Tenders, Door Tenders, Electrical Work Tenders, Fan and Blower Tenders, G I Pipe Tenders, Hook Tenders, Isolator Tenders, Light and Bulb Tenders, M S Pipe Tenders, M S Plate Tenders, Metal Box Tenders, Metal Products Tenders, Metal Sheet Tenders, Painting Work Tenders, Pipe- Plastic Tenders, Plastic Containers Tenders, Rod Tenders, Sand Tenders, Switches/Plug Tenders, Wire And Cable Tenders